Argo Vanguard 2 Service-Handbuch - Seite 11
Blättern Sie online oder laden Sie pdf Service-Handbuch für Geländewagen Argo Vanguard 2 herunter. Argo Vanguard 2 16 Seiten. Ducting & exhaust
Ducting & Exhaust
Installing the Muffler (Response, Vanguard2 and Vanguard Models)
1.
Install the muffler
On vehicles manufactured from S6999, SN8138, RB12075 and prior to S13434,
N13436, R19647:
i.
Assemble the muffler into the exhaust ducting aligning the tailpipe with the outlet
hole in the exhaust screen. The tailpipe should be facing slightly down and towards
the rear of the vehicle. Photo DE-27
ii
Connect the extension springs between the muffler and exhaust manifold.
On 6x6 Vanguard vehicles produced prior to S8131, the outlet pipe of the muffler is
straight cut. This tailpipe protrudes straight out of the exhaust screen. Refer to the
illustration in the appropriate parts manual for vehicles manufactured in this serial
number range.
All vehicles manufactured from RB12075, SN7841, S8131 and prior to R19647, S13434
& N13436 are as in Photo DE-27.
On models manufactured from R19647, S13434 & N13436:
i.
Reassemble the muffler to the engine and torque to specifications.
ii
Slip the tailpipe, from the engine compartment side, through the exhaust screen hole
and connect at the muffler with 2 extension springs. Photo DE-28
2.
Reinstall the exhaust duct cover using the appropriate hardware refering to the illus-
trated parts manual.
6x6 Vangards manufactured prior to S8131, utilize a shroud below the muffler as well.
Ontario Drive & Gear Limited
PH.(519)- 662-2840 FAX (519)- 662-2421
DE-27
DE-10
Argo Service Manual
DE-28
www.odg.com