Digitrax DS74 Handbuch - Seite 7

Blättern Sie online oder laden Sie pdf Handbuch für Kontrolleinheit Digitrax DS74 herunter. Digitrax DS74 8 Seiten. Complete train control

Digitrax DS74 Handbuch
6.2 Reading and Editing a DS74's routes:
using a suitable DT602 plugged into LocoNet, press the; Menu>3>4 keys to enter
Route Editor menu. If any DS74 is on LocoNet, the DT602 will beep after about
one second and show "DS7x" routes at the D soft key position.
1.
Press the D soft key to now enter the
"Selecting DS7x device " screen ,
2.
Rotate the LH encoder knob to under-
line the DS74 to edit routes on,
3.
Now press DOWN the LH encoder knob
to read in and display the Routes of the
selected DS74, as shown in adjacent
"EDIT DS7x Rt#" screen.
4.
The LH encoder knob now selects a
Route# and the RH encoder selects the
black outlined Entry# to edit. Soft A key
will toggle the entry from T to C direc-
tion choice. Numeric keys will change
the SW# in the outlined Entry position.
"Add" soft key allows inserting another
entry at current position and "Delete"
will remove the current entry. The "SW
test" will send just the outlined switch#
and direction to LocoNet.
5.
After edit of a Route is complete be sure to press the "Save" soft key to
update this in DS74 Route to non-volatile memory. Press "X" to exit.
6.3 Programming DS74 CVs on LocoNet:
a suitable DT602; press Menu>2>1 keys to enter Operations Mode programming.
Press the F "SWITCH" soft key to enter the "Ops Switch" mode program-
1.
ming screen as shown adjacent. This
example screen shows CV11 selected for
a DS74 with BASE address of SW1.
2.
Use the LH and RH encoder knobs to
select the SW# that you wish to modify
a CV on. DS74's CV11 to CV15 access the
40 OPSW bit settings.
3.
For example; at CV11 press the "CV-
DATA" soft key to change to CV data
entry and press the number 5 then press
"WRITE" key. This now configures the
8 OPSW bits in CV11 to 5, forcing this
DS74 to change to Light mode with 8
on/off outputs. A value of 00 in CV11
will return to factory default Pulse-sole-
noid mode. A CV11 value 0f 01 sets Slow
motion output mode.
4.
Be careful changing the values in
© 2021 Digitrax, Inc.
CS Rt
EDIT DS7x Rt#
Entry# TOP of 8
0100c
0224t
DS74
Sw0005+04# 3122
DS7X Edit: LH knob selects
Thrown
CV Program Menu A:
Ops Switch ADR: 0001
CV Number:
CV data:
CVNUM
— 7 —
As for section 6.0,
SW test
Delete
01 of 8
Add
Save
As for section 6.0, with
LOCO
0011
0000
CVDATA
DONE
www.digitrax.com