Digitrax BDL16 Informationen zur Installation - Seite 4
Blättern Sie online oder laden Sie pdf Informationen zur Installation für Sicherheitssensoren Digitrax BDL16 herunter. Digitrax BDL16 10 Seiten. Loconet occupancy detector with rx4
TABLE I: BDL 16 Connector Printed Circuit Bboard Component Side
Pin
Name
Connect To
#
1
Zone A
Connection to booster for Zone A
2
Detection
Isolated track section for Detection Section 1
Section 1
(DS 1)
3
DS 2
Isolated track section for Detection Section 2
4
DS 3
Isolated track section for Detection Section 3
5
DS 4
Isolated track section for Detection Section 4
6
Zone B
Connection to booster for Zone B
7
DS 5
Isolated track section for Detection Section 5
8
DS 6
Isolated track section for Detection Section 6
9
DS 7
Isolated track section for Detection Sectio n 7
10
DS 8
Isolated track section for Detection Section 8
11
Ground**
LocoNet/BDL16 ground to Booster
case/common ground
12
AC Power 1*
Power input to BDL16 : AC 12V to 15V, or
+DC 12V to 15V
13
Zone C
Connection to booster for Zone C
14
DS 9
Isolated track section for Detection Section 9
15
DS 10
Isolated track section for Detection Section 10
16
DS 11
Isolated track section for Detection Section 11
17
DS 12
Isolated track section for Detection Section 12
18
Zone D
Connection to booster for Zone D
19
DS 13
Isolated track section for Detection Section 13
20
DS 14
Isolated track section for Detection Section 14
21
DS 15
Isolated track section for Detection Section 15
22
DS 16
Isolated track section for Detection Section 16
Note that all connector pins except 11/M and 12/N are paired top (com-
ponent side) and bottom(solder side) of the PCB(printed circuit board).
For 6A current rating with 3A connector pins, track/zone wires must be
connected to both pin pairs: e.g., Zone A = pins 1 & A.
6
TABLE I: BDL 16 Connector Printed Circuit Board Solder Side
Pin
Name
Connect To
#
A
Zone A
Connection to booster for Zone A
B
Detection
Isolated track section for Detection Section 1
Section 1
C
DS 2
Isolated track section for Detection Section 2
D
DS 3
Isolated track section for Detection Section 3
E
DS 4
Isolated track section for Detection Section 4
F
Zone B
Connection to booster for Zone B
H
DS 5
Isolated track section for Detection Section 5
J
DS 6
Isolated track section for Detection Section 6
K
DS 7
Isolated track section for Detection Section 7
L
DS 8
Isolated track section for Detection Section 8
M
LocoNet
LocoNet network, connect to RED/GREEN
wires if not using RJ12 jacks
N
AC Power 2*
Power input to BDL16: AC 12V to 15V, or
DC 12V to 15V return
P
Zone C
Connection to booster for Zone C
R
DS 9
Isolated track section for Detection Section 9
S
DS 10
Isolated track section for Detection Section 10
T
DS 11
Isolated track section for Detection Section 11
U
DS 12
Isolated track section for Detection Section 12
V
Zone D
Connection to booster for Z one D
W
DS 13
Isolated track section for Detection Section 13
X
DS 14
Isolated track section for Detection Section 14
Y
DS 15
Isolated track section for Detection Section 15
Z
DS 16
Isolated track section for Detection Section 16
Note some letters are not used on connector.
*These AC1/AC2 power connections should be made to supply only used by
BDL16(s).
**The Ground connection must be made to booster for correct BDL16 opera-
tion.
7