B.one B1MS02-ZW-AU Handbuch - Seite 7
Blättern Sie online oder laden Sie pdf Handbuch für Sicherheitssensoren B.one B1MS02-ZW-AU herunter. B.one B1MS02-ZW-AU 9 Seiten.
Ⅷ.ADVANCED CONFIGURATION
B.One Motion sensor offers a wide variety of advanced configuration settings. Below parameters
can be accessed from main controllers configuration interface.
Parameter NO. 12 MOTION SENSOR'S SENSITIVITY
The higher the value, the more sensitive the PIR sensor.
0 – Disabled motion detection
Available settings: 1-8
Default setting: 8
Parameter size: 1 [byte]
Parameter No.14 ENABLE/DISABLE BASIC SET COMMAND
Motion sensor can send BASIC SET command to nodes associated with group 2 when motion is
triggered.
0 – Disable.
1 – Enable.
Default setting: 0
Parameter size: 1 [byte]
Parameter No.15 VALUE OF THE BASIC SET
B.One Motion Sensor can reverse its value of BASIC SET when motion is triggered.
0 –Send BASIC SET VALUE = 255 to nodes associated with group 2 when motion alarm is triggered.
Send BASIC SET VALUE = 0 to nodes associated with group 2 when motion alarm is canceled.
1 –Send BASIC SET VALUE = 0 to nodes associated with group 2 when motion alarm is triggered.
Send BASIC SET VALUE = 255 to nodes associated with group 2 when motion alarm is canceled.
Default setting: 0
Parameter size: 1[byte]
Parameter No.18 MOTION ALARM CANCELLATION DELAY
Motion alarm will be cancelled in the main controller after 3 seconds, the alarm cancellation can
be delay by this parameter. Any motion detected during the cancellation delay time countdown
will result in the countdown being restarted.
Available settings: 0-65535 (seconds)
Default setting: 0 (seconds)
Parameter size: 2[byte]