Value = 1 Si-01TC, Si-01TCext or Si-01TC-T from Mencke & Tegtmeyer (Sensor Box) connected
5.2 Setting the module temperature of Sensor Box
Parameter number 211: Module-temperature sensor type of sensor Box
Menu
Short description
Default Value
Value = 0 no module temperature sensor connected
Value = 1 PT1000 sensor connected
Value = 2 Type LM35 temperature sensor (included in the Sensor Box) connected
Parameter number 212: Ambient-temperature sensor type
Menu
Short description
Default Value
Value = 0 no module temperature sensor connected
Value = 1 PT1000 sensor connected
Value = 2 Type LM35 temperature sensor connected (only a single LM35 is possible per inverter)
6 Evaluating the Sensor Data by the Inverter
Parameter number 17: Module of Sensor Box
Menu
Short Description
Unit
The instantaneous module temperature can be read out here when a sensor is connected.
Parameter number 18: Ambient temperature
Menu
Short Description
Unit
The instantaneous ambient temperature can be read out here when a sensor is connected.
Parameter number 19: Irradiation sensor, external of Sensor Box
Menu
Short Description
Unit
The instantaneous irradiation can be read out here when a sensor is connected.
_____________________________________________________________________________
4
Environment
TYPTM
0
Environment
TYPTA
0
Environment
TM
°C
Environment
TA
°C
Environment
IRR
2
W/m