Incorrect Selection
If an incorrect parameter is entered, a message will indicate this on the db Enline unit.
User Authentication
Once the door identification parameters have been correctly entered, the user must then
authenticate. This will determine whether the user has access to the specified door. The db Enline
II unit allows up to two credentials to be used for authentication, PIN and fingerprint. The db
Enline III unit allows up to three credentials to be used for authentication, PIN, RFID card and
fingerprint. The required credentials are configured through the DAS-SQL Management Software.
The user must provide the credentials as requested by the db Enline unit:
Access Granted/Denied
Based on verification of the credentials, access is either granted or denied.
Following a successful access, the specified door will unlock.
Time Restriction
It's also possible to restrict what times a user has access to each door. The db Enline unit will
check that the user is attempting access within their permitted times. If access is attempted
outside a user's permitted times, the following message will be displayed.