Acuity Brands Sensor Switch WSX PDT 2P Schnellstart-Handbuch
Blättern Sie online oder laden Sie pdf Schnellstart-Handbuch für Schalter Acuity Brands Sensor Switch WSX PDT 2P herunter. Acuity Brands Sensor Switch WSX PDT 2P 4 Seiten. Wall switch sensor w / convertible neutral / no neutral wiring, passive infrared (pir) or dual tech (pdt)
PRODUCT OVERVIEW
The WSX Family of wall switch occupancy sensors provides simple and cost effective
solutions for commercial and residential lighting control applications. All WSX
Family sensors have a stylish low profile appearance, soft-click buttons, and provide
small motion detection up to 20 ft (6.10 m), making them perfect for private
offices, private rest rooms, closets, copy rooms, or any other small enclosed space.
Additionally, all WSX Family sensors have a patent-pending wiring method that
enables them to function either with or without a neutral connection. WSX units
come pre-configured for wiring without a neutral, however if connection to neutral
is required by code, contractors can convert the unit in seconds (see page 3).
All WSX Family sensors utilize 100% digital Passive Infrared (PIR) detection.
Dual Technology (PDT option) versions add Microphonics detection and are
recommended for offices and rooms with obstructions. Additional versions include
units with dual relays - perfect for bi-level applications, and units with an integrated
nightlight - perfect for restrooms and residential applications.
SENSOR OPERATION — WSX sensors detect changes in the Passive Infrared (PIR)
energy given off by occupants as they move within the field-of-view. In an Auto-On
sensor, once occupancy is detected, an internal relay switches on the connected
lighting load. In a Vacancy (Manual On) sensor, the unit's push button must first be
pressed to initiate the lights on. In a dual relay sensor, once occupancy is detected
the unit will automatically close Pole 1's relay while still requiring Pole 2's push-
button be pressed in order to close Pole 2's relay. All modes are user adjustable (see
On Modes section).
After the lights are turned on, an internal timer keeps them on during brief periods
of inactivity. Once the time delay has expired, lights are turned off automatically.
The default time delay is 10 minutes - chosen in order to maximize energy savings
while preventing false-offs. This timer is programmable from 30 seconds to 30
minutes, and is reset every time occupancy is re-detected. Patented LampMaximzer
technology is also present in these sensors, providing an additional minimum on
time (disabled by default) to be utilized if desired.
WSX sensors with Passive Dual Technology (PDT option) first see motion using
Passive Infrared (PIR) and then engage Microphonics to listen for sounds that also
indicate continued occupancy. This patented technology dynamically adapts a
sensor to its environment by filtering out constant background noise and detecting
only noises typical of human activity.
FEATURES
• 100% digital PIR detection - excellent RF immunity
• Ruggedized assembly, vandal resistant lens standard
• Small motion detection to 20 ft
• Dual Technology (PDT) utilizes PIR / Microphonics
detection (patented)
• 100% passive detection, no potential for
interference with other building systems
• Self-grounding mounting strap
• White LED status indicator
Sensor Switch 900 Northrop Road, Wallingford, CT 06492 Phone: 1.800.PASSIVE sensorswitch.com ©2013 Acuity Brands Lighting, Inc. All rights reserved 07/01/13
Catalog Number
Notes
WSX
FAMILY
KEY OPTIONS
NIGHT LIGHT (NL)
Ideal for bathrooms (hotel / hospital) or residential applications
• Ultra low power White LED night light (24/7 operation)
• Capable of powering over Ground (no Neutral required)
• Manual On / Auto Off operation of lights (default)
• Available with Single or Dual Relays
Dual Relay (2P)
Ideal for bi-level switched rooms or restroom with light & fan
• Includes two isolated relays, Pole 1 defaulted to Auto On, Pole 2 to Vacancy
• Enables separate time delay per pole - programmed via each pole's push-button
• UL listed to switch different loads per pole - e.g. 277 VAC lights on Pole 1 and 120
VAC fan on Pole 2
LOW TEMPERATURE / HIGH HUMIDITY (LT)
Required for cold / humid areas
• Device electronics are coated for corrosion resistance
• Operates down to -40º F/C (-4º F / 20º C for PDT)
• Device accommodates powering over ground or
neutral connection (patent pending)
• Ultra low current leakage (<0.5 mA) when
connected via ground
• Fully meets NEC 2011 Section 404.2C neutral
requirements - no current leakage to ground when
connected to neutral
• Line power and load wires are interchangeable -
impossible to wire backwards (patented)
• Compatible w/ LEDs, Electronic & Magnetic Ballasts,
CFLs, & Incandescents
WALL SWITCH SENSOR w/
CONVERTIBLE NEUTRAL / NO NEUTRAL WIRING,
PASSIVE INFRARED (PIR) or DUAL TECH (PDT)
WSX
WSX NL
WSX PDT
WSX PDT NL
• Photocell standard (disabled by default) - prevents
lights from initially turning on if sufficient daylight
is present, but does not turn lights off. Photocell not
available in Night Light or Vacancy only versions.
• Integrated LampMaximizer minimum on time
(patented) provides increased fluorescent lamp life -
disabled by default
• Push-button programmable without removing cover
plate - adjustable time delays & operating modes
• Non-volatile settings memory
• Includes wall plate (screwless sold separate)
Type
WSX 2P
WSX PDT 2P
1 of 4