ENTERING A KNOWN UNIT WEIGHT

 If the unit weight is already known then it is possible to enter that value
using the keypad.
 Enter the value of the unit weight using the numeric keys followed by
pressing the U.Wt key. The "Unit Weight" display will show the value
as it was entered.
 Add the sample to the scale and the weight will be displayed as well as
the quantity based upon the unit weight.
 When weighing in kilograms the unit weight is shown in grams. When
weighing in pounds the unit weight is displayed in pounds.

STORING A UNIT WEIGHT

Up to 10 unit weights may be stored in the scale memory and recalled later.
 Obtain the unit weight by sampling or by entering it as described in the
above sections.
 Press and hold the U.Wt key for approximately 2 seconds
 Press any of the numeric keys (0-9) to store the unit weight in the
corresponding memory.

RECALLING A STORED UNIT WEIGHT

 Clear the scale display and set the zero point and Tare any container
on the scale.
 Press and release the numeric key corresponding to the location of the
stored unit weight.
 The Count Display will begin flashing.
 Now double click U.Wt key (Press twice quickly)
 The stored unit weight will appear in the unit weight display and you
may begin counting..