6
Detector Installation
Important! Prior to installation, read both "Operation" and "Selecting the mounting location"
sections carefully.
1. Install the detector in such manner that the intruder is
most likely to cross the detection area from side to side.
3. Make sure to attach the metal bracket to a leveled
straight and firm wall, leaving 10cm (3.9 inches) from
the top and 10cm (3.9 inches) from both sides, for easy
installation and maintenance.
5. Open the detector unwinding the bottom screw.
2. The detector is to be installed at height of 2.1m (6.9
ft.) for Grade 2 or 1.2m (3.9 ft.) for Grade 3
4. Placing the detector on perpendicular wall is
required for guarding a side window opening.
Alternately the Outdoor Mounting bracket can be
installed on the same wall, allowing the detector
beam to be rotated towards the window.
6. Release the rear metal bracket by unwinding
internal bottom screw.
7