Siren's Jumper's MODE SET-UP
Jumper No.
A
B
C
D
Learn the FW2 Siren with SERENITY
There are 3 options 
 
Option 1: 
Step 1: Insert the battery to the Siren while pressing learn button‐>The FW2‐Siren led 
Step 2: Enter to the Installer mode P000000E‐> Enter P64 ʹLearn radio output'. 
 
Step 3: Use the +, ‐ keys to Select the required learned output number 
 
Step 4: Press the Enter key. 
 
Step 5: Press on the learning button (Siren), the control‐panel will display the message 
 
Step 6: To test functionality of the serenity after learning refer to ʺfunction testing 
NOTE: During the learning process or the operation of the Siren is recommended to 
 
Function if = O (Open)
Not in used for RUNNER 2 and
SERENITY control panels
NO Flashes with ARM/Disarm
NO Beeps with ARM/Disarm
2 Min Time out
Using Installer programming mode:
will blink for 30 sec ‐> the FW2‐Siren is now ready for use. 
ʺCompleteʺ at the end of the learning process ‐>The Siren led will blink , for 
3 sec to indicate that the FW2‐Siren was learned. 
after FW2 Siren learningʺ page 10 
keep a distance as two meters between the serenity C.P to the Siren. 
Function if =1 (Close)
Flashes appear with ARM/Disarm
Arm: 2 Flashes (@LOW BAT 3+3
Flashes)
Disarm: 1 Flash (@LOW BAT 2
Flashes)
Beeps sound with ARM/Disarm
Arm: 2 Beeps(@LOW BAT 3+3
Beeps)
Disarm: 1 Beep (@LOW BAT 2
Beeps)
15 Min Time out
8