The sensitivity adjustment is performed by setting a potentiometer and MW jumper as
follows (using clock needle positioning):
Environment type
Low risk
Risk
High risk
Very high risk
Noisy area
Extremely Noisy area
Note: Adjust sensitivity according to environmental conditions!

8.3 Pet immunity setting

The EDS-2000 has a detachable Pet immunity filter. As such the Pet immunity level may vary
between:
1. 36kg (80 lbs) with pet immunity filter assembled
2. 15kg (33 lbs) if no pet immunity filter is used.
The installer is to select the requested Pet immunity level.
The filter is to be installed according to the following orientation:
Potentiometer position
4 o'clock
12 ~ 3 o'clock
3 ~ 4 o'clock
12 ~ 3 o'clock
9 ~ 12 o'clock
8 o'clock
This side up!
14
MW jumper position
H
H
L
L
L
L