Crow EDS-3000 Installationsanleitung und Benutzerhandbuch - Seite 14
Blättern Sie online oder laden Sie pdf Installationsanleitung und Benutzerhandbuch für Zubehör Crow EDS-3000 herunter. Crow EDS-3000 20 Seiten. Outdoor double optics pir + mw detector with pet immune

• High risk: Unstable environment with different types of vegetation and grass and
puddles.
• Very high risk: Unstable environment with winds and small pets, rats, mice, birds.
• Noisy area: Unstable environment with vegetation and water sources like swimming
pool, lake, canal, weed as well as small pets like cats and rabbits.
• Extremely Noisy area: Very unstable environment subjected to wind, snow, rain, with
vegetation, water and large pets like dogs.
For example:
If detector is used for 13m (42 ft) range in open space with sunlight and pets, set switch to
position 9.
8.4 Indications setting
LED OFF
alarm shop
Factory default setting
The EDS-3000 has two types of indications:
1. LED
2. Buzzer
The installer may determine both indications' operation during detection (ON or OFF) by using
switch number "1" for the buzzer and switch number "2" for the LED.
(Setting the buzzer ON gives the installer the ability to hear the beep on each detection for 1.8
seconds during the adjustments and a walk test. After the process it is recommended to switch
the buzzer OFF)
ON
OFF
14
ON
Buzzer ON
OFF
Factory default setting