3. DESCRIPTION OF THE DEHUMIDIFIER
Control panel
Clean filter is important:
The filter must be vacuumed frequently. A clean air filter is important to ensure a good drying effect and a low power
consumption. Most problems with a drying rotor-based dehumidifier are caused by poor cleaning. It is therefore important
to ensure clean air filters. Never use the dehumidifier without a filter. During normal use, the filter must not be replaced, it
lasts the entire life of the appliance.
4. CONTROL PANEL
On and off:Here the dehumidifier is switched on or off. The correct mode (button 2) and humidity (button 4) must be
set. The fan will always be in operation 4 minutes after the dehumidifier is switched off (power lamp lights up
red). This is to cool the dehumidifier.
It is important that the air damper is always open when the dehumidifier is started. It must be
closed when not in use so that nothing gets into the dehumidifier.
2. Fan speed (Mode):There are 3 fan speeds that can be used. Press the button to set the desired
speed.
3. Time setting (Hours): If clothes are to be dried or you want the dehumidifier to run for a short
period, this function can be used. Press the button to select how many hours the dehumidifier
should be in operation. The dehumidifier must be restarted after this period.
Handle
Air damper
Connection
for hose
Cover
Float
Water tank
Air filter
4
Intake for air
Hygrostat