Toshiba TLP510E Service-Handbuch - Seite 16
Blättern Sie online oder laden Sie pdf Service-Handbuch für Projektor Toshiba TLP510E herunter. Toshiba TLP510E 33 Seiten. 3lcd data projector
Auch für Toshiba TLP510E: Technisches Schulungshandbuch (47 seiten)
Adjust Items
Input Signal
1. Input level adjustment
1-1. Pedestal level
RGB signals
adjustment
(pedestal level)
1-2. Gray scale level
RGB signals
adjustment
(gray scale)
1-3. Video signal input
Video signal
level adjustment
(gray scale)
2. Bias adjustment
2-1. Bias adjustment 1
RGB signals
(gray scale)
2-2. Bias adjustment 2
RGB signals
(gray scale)
2-3. Bias adjustment 3
RGB signals
(gray scale)
3. Bright/Contrast
RGB signals
adjustment
(gray scale)
Table 4-1-1
Test
Equip-
Test Point
Adjust Key
ment
Oscillo-
T13 (R)
scope
T15 (G)
T17 (B)
Oscillo-
T13 (R)
scope
T15 (G)
T17 (B)
Oscillo-
T13 (R)
scope
T15 (G)
T17 (B)
Digital
T04 (R)
voltmeter
T06 (G)
T08 (B)
Digital
T05 (R)
voltmeter
T07 (G)
T09 (B)
Digital
T20 (G)
voltmeter
T19 (G)
Oscillo-
TP401 (R)
(bright)
W13
scope
TP401 (R)
(contrast)
W11
TP402 (R)
(bright)
W14
TP402 (R)
(contrast)
W12
TP501 (G)
(bright)
W23
TP501 (G)
(contrast)
W21
TP502 (G)
(bright)
W24
TP502 (G)
(contrast)
W22
TP601 (B)
(bright)
W33
TP601 (B)
(contrast)
W31
TP602 (B)
(contrast)
W34
TP602 (B)
(bright)
W32
1-14
Adjust Value
• See the
VSB
illustration right.
VSB
VSB
A = 1.75V ± 50 mV
VGR
A = 1.75V ± 50 mV
VGG
A = 1.75V ± 50 mV
VGB
A = 1.75V ± 50 mV
VGR
A = 1.6V ± 50 mV
VGG
A = 1.75V ± 50 mV
VGB
6V ± 20 mV
W16
6V ± 20 mV
W26
6V ± 20 mV
W36
6V ± 20 mV
W15
6V ± 20 mV
W25
6V ± 20 mV
W35
6V ± 20 mV
W52
6V ± 20 mV
W53
A = 2V ± 50 mV
B = 3V ± 50 mV
TP401 adjustment
value ± 30 mV
TP401 adjustment
value ± 30 mV
A = 2V ± 50 mV
B = 2.9V ± 50 mV
TP501 adjustment
value ± 30 mV
TP501 adjustment
value ± 30 mV
A = 2V ± 50 mV
B = 2.9V ± 50 mV
TP601 adjustment
value ± 30 mV
TP601 adjustment
value ± 30 mV
Note
• Select
and adjust until
VSB
signal shows flat.
Blanking
NG
OK
(A)
• Click
to set video input
IN2
mode.
(A)
• Adjustment value for bias
adjustment 1:
± 10 mV
• Click
on Normal menu to
PJ0
set forward scan mode and
then start the adjustment.
Next click
to set reverse
PJ1
scan mode and perform
adjustment.
• Adjustment value for bias
adjustment 1:
± 10 mV
B
A