3. No-load protection;
4. Overvoltage/undervoltage protection;
5. The machine will be off automatically without pressing buttons in
three minutes on the condition of shutting down.
Predictions on Abnormal Indication
Codes
Fault Types
E1
Excessively high or low city voltage
Over-temperature or temperature
E2
probes are abnormal
NTC resistance is abnormal in the
E3
CN1 of the circuit board.
Infrared temperature probes break
E4
down
The warning indication of actual
infrared temperature that is more
E5
℃
than 200
The motor is stuck or the circuit is
E6
abnormal
The winding displacement that
connects keyboard plates and
E7
heating plated is abnormal
The winding displacement that
connects keyboard plates and
E8
heating plated is abnormal
No heating or abnormal heating
(the inner pot has been installed
E9
properly)
Solutio
Wait for the proper usage of the
voltage
Wait for the restart of the machine
after cooling. If it is still abnormal,
please send it to the after-sales
service maintenance department.
Send it to the after-sales service
maintenance department.
Send it to the after-sales service
maintenance department.
Wait for the restart of the machine
after cooling. If it is still abnormal,
please send it to the after-sales
service maintenance department.
Take out the inner pot to install again
and restart. If it is still abnormal,
please send it to the after-sales
service maintenance department.
Send it to the after-sales service
maintenance department.
Send it to the after-sales service
maintenance department.
Send it to the after-sales service
maintenance department.
Technical Parameters
Place of Origin
Boundary Dimension
Length 310 ×width 370×height 365mm
Ways of heating
Ways of controlling
Net Weight
Gross Weight
Volume of the cup body
Control panels
Rated voltage
Rated power
Length of the power cord
Other functions
China
IH electromagnetic heating
Microcomputer control
7.4 kg
8.5 kg
6L
Touch screens
220V~50HZ
2000W
1.08 m
Turning adjustment
Fire adjustment
Time adjustment