CAUTION: Do not handle the antenna tips, especially after they are connected to the access
point, as this could lead to electrostatic discharge (ESD), which could damage the equipment.
The installation CD includes the User Guide, which contains more detailed information on planning, installing
and configuring the device. Additional tools and utilities are provided to assist with the management of your
network. See "Documentation and Software Utilities" on page 6 for instructions.
3

Connect the Power

The access point complies with the IEEE 802.3af power-over-Ethernet standard. It receives power over a
standard category 5 straight (8-wire) Ethernet cable. There are two ways to supply power to the access point
(refer to the illustration below):
Use the supplied 3Com Integrated Power-over-Ethernet power supply. In this case, you need
o
to supply a second Ethernet cable to connect to the wired LAN.
Connect the access point directly to your own power-over-Ethernet hub or switch, which must
o
also comply with the IEEE 802.3af standard.
"To Access Point"

Using the Power Supply

Using the Power Supply
The power supply can be located at any point between the access point and the LAN access port, wherever a
convenient power outlet exists. If you supply your own Ethernet cable for connecting power, be sure that it is
standard category 5 straight-through (8-wire) cable that has not been altered in any way. Use of nonstandard
cable could damage the access point.
Refer to the illustration above, and follow these steps:
1
Connect one end of the Ethernet cable to the Ethernet port on the access point.
2
Connect the other end of the Ethernet cable to the port labeled To Access Point on the power
supply.
3
Connect the power cord to the power supply and plug the cord into a power outlet.
"To Hub/Switch"
Using A Power-over-Ethernet
LAN Port