Dimplex AC45N Installations- und Betriebsanleitung - Seite 4
Blättern Sie online oder laden Sie pdf Installations- und Betriebsanleitung für Heizgerät Dimplex AC45N herunter. Dimplex AC45N 4 Seiten. Ac air curtains
Auch für Dimplex AC45N: Anleitung (3 seiten), Benutzerhandbuch (4 seiten), Installations- und Betriebsanleitung (12 seiten), Schnellstart-Handbuch (19 seiten), Handbuch (20 seiten)
Maintenance
WARNING: DISCONNECT SUPPLY before carrying out
maintenance.
Thermal Safety Cut-outs
The power supply to the heating elements will be interrupted
if one or a combination of the following abnormal events oc-
cur.
1 .
Air inlet or outlet grilles are obstructed.
2.
Internal ventilation is impaired due to build up of dust
and fluff.
3.
Blower unit stalls.
Note : If the cut-out operates, the fan may continue to run
impairing the performance of the heater. The heater must be
turned off immediately.
To reset the cut-out on all models see Procedures below :
reset button
on cut-out
centre panel
on cut-out
Procedure for resetting cut-out (AC3N, AC45N
& AC3RN)
Establish cause and eliminate. Reset thermal cut-out(s) by
depressing black button on side of cut out as described in
steps 2 - 4 below.
1.
Disconnect power supply.
2.
Pass
flat
head
outlet grille to centre panel side of reset button.
3.
Press
buttons
reset cut-outs (see
4.
Remove screwdriver carefully.
5.
Turn on supply.
The product complies with the European Safety Standards EN60335-2-30 and the European Standard Electromagnetic Compatibility
(EMC) EN55014, EN60555-2 and EN60555-3 which cover the essential requirements of EEC Directives 73/23 and 89/336
Glen Dimplex UK Limited
Millbrook House
Grange Drive
Hedge End
Southampton
Hampshire. SO30 2DF
[c] Glen Dimplex UK Limited
All rights reserved. Material contained in this publication may not be reproduced in whole or in part, without prior permission in writing of Glen Dimplex UK Limited.
see detailed
view below
outlet grille
element
Fig. 16
cut-out
screwdriver
through
in
directions
shown
Fig.16).
Cut-out clicks when reset.
UK customer help line (8.00AM – 6.00PM Mon-Fri; 8.30AM-1.00PM Sat)
Customer Services:
Republic of Ireland
Procedure for resetting cut-out (AC6N only)
1. Disconnect power supply.
2. Determine what has caused the cut-out to operate and
rectify.
( Note : This should only be undertaken by competent per-
sons with experience of repairing electrical appliances and in
full knowledge of the possible hazards involved ).
3.
After a short time delay to allow the appliance to cool
down, all that is required to return the heater to normal opera-
tion is to switch the electricity supply back on.
Cleaning
WARNING: DISCONNECT SUPPLY before carrying out
maintenance.
External appearance can be maintained by wiping occasion-
ally with a damp cloth ; for stain removal, a weak soap solu-
tion can be applied with a cloth and the surface wiped dry.
Care must be taken to avoid any moisture ingress into the
product.
After Sales Service
Your product is guaranteed for one year from the date of
purchase.
Within this period, we undertake to repair or exchange this
product free of charge (subject to availability) provided it has
been installed and operated in accordance with these in-
structions.
Your rights under this guarantee are additional to your statu-
tory rights, which in turn are not affected by this guarantee.
Should you require after sales service you should contact
our customer services help desk on 0870 727 0101. It would
assist us if you can quote the model number, series, date of
purchase, and nature of the fault at the time of your call. The
customer services help desk will also be able to advise you
should you need to purchase any spares.
Please do not return a faulty product to us in the first instance
as this may result in loss or damage and delay in providing
you with a satisfactory service.
Please retain your receipt as proof of purchase.
air
to
Tel.
Fax.
e-mail
Tel.
0870 7270101
0870 7270102
01 8424833