3. Operation
3.1 Before Startup
a. Select the correct nose assembly for the specific fastener to be installed.
(See section 3.2 for the steps of nose installation)
b. Turn the hydraulic system to OFF and disconnect the power supply from unit,
then connect the tool hoses to the tool;
c. Connect the tool's control switch electrical cord to the hydraulic unit.
d. Connect the hydraulic unit to the power supply. Turn on the unit. Press the
tool's trigger a few times to circulate the hydraulic fluid. Observe the action
of the tool and check for any leaks.
e. Check the PULL and PUSH pressure, if necessary, adjust to the proper
pressure.
3.2 Assemble Nose to Tool
STEP1: Install the ejector into the hole that is inside of the anvil;
STEP2: Install the guiding sleeve into the hole of the rubber jaw.
STEP3: Install the rubber jaw into the collect assembly.
STEP4: Use circlip pliers to install the retaining ring-45 to the rear end of the guiding
sleeve, then fix the guiding sleeve in the collect assembly.
STEP5: Thread the collect assembly to the piston.
STEP6: Tighten the 3 set screws from the piston.
STEP7: Install the anvil into the collect assembly as shown in the Nose assembly
diagram above;
STEP8: Lock in the anvil and the cylinder assembly with retaining ring-56.
7