The heating device may only be installed as shown, i.e.
on a horizontal, even surface. Use on deep-pile carpets
is not permitted. Please exercise caution when install-
ing it in front of flammable objects. Installation below a
wall socket is not permissible. Minimum clearances
must be observed.
In addition, a minimum clearance of 500 mm must be
maintained between flammable objects e.g. curtains,
towels or heat-sensitive plastics and the front of the
unit.
2.1 Use in the bathroom
Use the device such that it is not possible for someone
in the bath or shower to touch the control elements.
In accordance with VDE 0100 Part 701, the device
must not be fitted in protected zones 0 and 1. The de-
vice must receive its power supply via a protective re-
sidual current device (FI).
3. Installation of the supporting feet
Do not operate the heating device without the feet sup-
plied being fitted.
Model WW 101 E is supplied without casters.
4. Electrical Connection
The voltage specified on the type plate must match the
local mains voltage.
The device plug must always be accessible.
EN-6
Supporting feet, casters and
the two fixing screws are
provided loose.
Screw down supporting feet
as shown and attach cast-
ers if required.
WW101_201e_dimplex_gb.fm · 10/17/C
5. Operation
5.1 Thermostat
The room tempera-
ture
is
regulated
using the infinitely
adjustable
thermo-
stat. If the rotary
knob is set to the
lowest setting i.e. to
the extreme left (see
figure), the thermo-
stat
switches
the
heating device on at
an ambient tempera-
ture of approx. 5° - 8°
C. During boost (see
below), the thermostat does not work
5.2 Switches and buttons
The device has one On/Off switch and four buttons with
indicator lamps. The buttons can be used to select the
following functions:
5.3 Heating level I, heating level II
Various levels of heating output can be set, see table.
Button for
WW 101 E
Heating level I
400 W
Heating level II
600 W
Heating level
1000 W
I and II
5.4 Comfort
The temperature set on the thermostat's rotary knob is
taken into account.
5.5 Setback
The temperature set on the thermostat's rotary knob is
reduced by around 4°.
5.6 Boost
The temperature set on the thermostat's rotary knob is
not taken into account. Heating levels I and II are acti-
vated.
Press "Boost" button once: light is red; boost for 30
minutes. Press "Boost" button twice: light is green;
boost for 1 hour.
Press "Boost" button again: boost deactivated.
ATTENTION!
Depending on the size of the room, heat requirement
and thermostat setting, rooms may overheat if the
heating is not controlled. This can be dangerous for
people who are not able to leave the room as it gets too
hot!
WW 101/151/201 E
WW 151 E
WW 201 E
500 W
750 W
1000 W
1250 W
1500 W
2000 W