Please read this and other device guides carefully.Failure to follow the recommendations set forth by Aeotec Limited may
be dangerous or cause a violation of the law. The manufacturer, importer, distributor, and/or reseller will not be held
responsible for any loss or damage resulting from not following any instructions in this guide or in other materials.
Only a licensed electrician with knowledge and understanding of electrical systems and safety should complete the
installation.
The maximum amperage rating for Nano Shutter is 2.5A for each slot and 5A for both when connecting a motor load
(COSφ=0.4, L/R=7ms)
Keep product away from open flames and extreme heat. Avoid direct sun light or heat exposure.
Nano Shutter is intended for indoor use in dry locations only. Do not use in damp, moist, and / or wet locations.
Install the Nano Shutter.
Nano Shutter installs behind a switch or a momentary push button. It works with only 3-wire (with neutral) lighting setups,
though each installation of Nano Shutter is accordingly slightly different:
1. Shut off the main circuit breaker of your home for safety during the installation and ensure the wires are not short
circuited during the installation which will cause damage to the Nano Shutter.
Note: Your home's main circuit breaker must support the overload protection for safety.
2. Preparing connection wires
14 AWG power wires for Input / Output.
18 AWG copper wires for external manual switch.
Use the wire stripper cut the metallic part of the connection wire and make sure the length of the metallic part is about
5mm.