Aeon Labs Aeotec Handbuch - Seite 5
Blättern Sie online oder laden Sie pdf Handbuch für Messgeräte Aeon Labs Aeotec herunter. Aeon Labs Aeotec 9 Seiten. Home energy meter
Auch für Aeon Labs Aeotec: Benutzerhandbuch (7 seiten), Benutzerhandbuch (11 seiten)
always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a 'Basic Set' Command.
Association Groups:
Group Number
1
2
3
Configuration Parameters
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further
enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the
desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the
same logic applies: Values greater than 32768 may needed to be given as negative values too.
Parameter 2: Energy detection mode
For parameters of 101, power, energy detection mode
Size: 1 Byte, Default Value: 0
Setting
0
1
2
3
Parameter 3: Selective reporting
Enable selective reporting only when power change reaches a certain threshold or percentage set in 4-11 below. This is used to reduce network traffic.
Size: 1 Byte, Default Value: 1
Setting
0
1
Parameter 4: Threshold change in wattage
Threshold change in wattage to induce a automatic report (Whole HEM).
Size: 2 Byte, Default Value: 50
Setting
0 - 60000
Parameter 5: Threshold change in wattage (Clamp 1)
Threshold change in wattage to induce a automatic report
Size: 2 Byte, Default Value: 50
Setting
0 - 100
Parameter 6: Threshold change in wattage (Clamp 2)
Threshold change in wattage to induce a automatic report
Size: 2 Byte, Default Value: 50
Setting
0 - 100
Parameter 7: Threshold change in wattage (Clamp 3)
Threshold change in wattage to induce a automatic report
Size: 2 Byte, Default Value: 50
Maximum Nodes
5
5
5
Description
report power, energy absolute value
report positive/negative power, report the algebraic sum energy
report positive/negative power, only report energy positive part (consuming electricity)
report positive/negative power, only report energy negative part (generating electricity)
Description
disable
enable
Description
Watt
Description
Valid value
Description
Valid value
Description
Send configured Value to devices
Send configured Value to devices
Send configured Value to devices