Sensor for each ash of the LED switches its output on for approx. 3 ms. This period is sufciently
short to avoid unwanted switching of relay contacts. For binary inputs, we recommend to set the
lter so as not to respond to pulses shorter than 3 ms.
Units Dinel NSSU, NDSU a NLCU with transistor switch ( T ) detects and transmitts these pulses
to the output.
Level state
* Variant E without LED state indicator
For security reasons, we recommend to set the mode O (normally open, sensor closes when immersed)
for minimum level detection. Any failure of the sensor or wiring is equally apparent as the emergency
level state. Analogously for the maximum level detection is recommended to set the mode C (normally
closed, sensor opens when immersed).