11 . o
rder
code
CLS – 23
Performance:
– Normal for non-explosive areas
N
– Extended temperature range variants for non-explosive
E
areas (without LED)
– High temperature variants for non-explosive areas
NT
–
(intrinsically safe) for hazardous areas
Xi
XiT –
(intrinsically safe), high temperature variants
12 . c
orrect
sPeciFication
CLS–23N–10–A–S–G3/8 cable 5 m
(N) For non-explosive areas; (10) Uncoated short bar electrode 30 mm, (A) Cable outlet with 5 m fixed cable; (S) 2-wire electronic
switch; (G3/8) Process connection with pipe thread G3/8"
CLS–23E–30–A–S–G1/2 E450 cable 10 m
(E) Extended temperature range performance for non-explosive areas; (30) Uncoated removable rod electrode; (A) Cable outlet with
10 m fixed cable; (S) 2-wire electronic switch; (G1/2) Process connection with pipe thread G1/2"; (E450) Electrode length 450 mm.
CLS–23NT–20–C–S–M18 E320
(NT) High temperature variants for non-explosive areas; (20) Partly insulated rod electrode (FEP); (C) Electrically connection with
connector; (S) 2-wire electronic switch; (M18) Process connection with metric thread M18x1.5; (E320) Electrode length 320 mm.
CLS–23Xi–11–C–R–NPT
(Xi) Intrinsically safe for hazardous areas; (11) Insulated (coated) short bar (PP) electrode 30 mm (C) Electrically connection with
connector; (R) NAMUR output type; (NPT) Process connection with sealing thread 1/2 – 14 NPT.
© Dinel, s.r.o.
CLS–23
–
–
–
–
examPles
E
Cable
Electrode length in mm
Process connection:
G3/8 – Pipe thread G 3/8"
G1/2 – Pipe thread G 1/2"
M18 – Metric thread M 18x1,5
M20 – Metric thread M 20x1,5
NPT – Sealing thread 1/2–14 NPT
Output type:
– PNP (Open collector)
P
– 2-wire electronic switch
S
– NAMUR (For Xi variants only)
R
Electric connection:
– Cable outlet (+ Spec. the length of the cable)
A
– Connector – (+ Spec. type of the socket)
C
except variant "A"
Type and electrode performance:
– Uncoated short bar, length 30 mm
10
– Insulated (coated) short bar (PP), length 30 mm
11
– Insulated (coated) short bar (FEP), length 30 mm
12
– Partly insulated rod (FEP), length 50 ... 1000 mm
20
– Fully insulated rod (FEP), length 50 ... 1000 mm
21
– Uncoated removable rod, length 50 ... 1000 mm
30
Length of cable in meters
(variant "A")
13