Servicing Instructions
10.3.6 Removing the fan
1. Disconnect electrical connections "O" and silicone pipe "P"
(F
.10.25);
IG
2. Remove screw "Q" and remove the fan collar clamp "R" (F
10.26);
3. Remove screws "S" (F
. 10.27);
IG
4. Remove fan and mounting plate (F
F
. 10.25
IG
O
O
F
. 10.26
IG
F
. 10.27
IG
S
S
F
. 10.28
IG
Supplied By www.heating spares.co Tel. 0161 620 6677
. 10.28).
IG
P
R
Q
S
10.4
Access to the Gas Valve
10.4.1. Removing the spark generator
.
IG
1. Disconnect ignition leads "T" by pulling upward
(F
. 10.29);
IG
2. Remove the screw "U" (F
3. Remove the spark generator by pulling forward from the gas
valve (F
. 10.31).
IG
F
. 10.29
IG
F
. 10.30
IG
F
. 10.31
IG
36
. 10.30);
IG
T
U