Ariston FAST EVO X ONT 14 EU Gebrauchsanweisung - Seite 24

Blättern Sie online oder laden Sie pdf Gebrauchsanweisung für Warmwasserbereiter Ariston FAST EVO X ONT 14 EU herunter. Ariston FAST EVO X ONT 14 EU 41 Seiten.

Ariston FAST EVO X ONT 14 EU Gebrauchsanweisung
Uređaj je opremljen s G filterom koji se nalazi na
ulazu hladne vode. Povremeno očistite hidraulični
sustav, ukoliko su prisutne nečistoće.
VAŽNO!
NEMOJTE UKLJUČIVATI UREĐAJ
BEZ FILTRA!
VAŽNO!
UKOLIKO JE UREĐAJ POSTAVLJEN U
PODRUČJU S TVRDOM VODOM ( > 200
MG/L) NEOPHODNO JE
POSTAVLJANJE OMEKŠIVAČA VODE
KAKO BI SE SMANJILO STVARANJE
KAMENCA U IZMJENJIVAČU TOPLINE.
JAMSTVO NE POKRIVA ŠTETU
NASTALU ZBOG KAMENCA.
Spajanje ispušnog sustava dimnih plinova
Uređaj treba biti spojen na ispušni sustav koji je u
skladu s važećim zakonom, te preporukama
proizvođača.
KADA SE KORISTI POSTAVLJANJE TIPA B,
PROSTORIJA U KOJOU JE POSTAVLJEN UREĐAJ
TREBA BITI VENTILIRANA PRIKLADNIM
DOVODOM ZRAKA KOJI JE U SKLADU S VAŽEĆIM
ZAKONIMA.
Prilikom postavljanja ispušnog sustava, vodite brigu o
brtvljenjima kako biste spriječili curenje dimnih plinova
u zračni krug.
UPOZORENJE!
NEMOJTE DIRATI ILI ISKLJUČIVATI
SENZOR DIMNIH PLINOVA. OVO MOŽE
UTJECATI NA PRAVILAN RAD
UREĐAJA.
U SUPROTNOM MOŽETE IZAZVATI
ULAZAK PLINA U PROSTORIJU GDJE
JE POSTAVLJEN UREĐAJ. OPASNOST
OD TROVANJA UGLJIČNIM
MONOKSIDOM.
Dio dimovodne cijevi koja prolazi kroz zid
mora biti okružen izolacijskim materijalom
(kao što je azbestna tkanina) barem 11 mm
debljine i duljine 300 mm, jer temperatura
dimne cijevi može premašiti temperaturu
okoline za više od 60K.
postavljanje
The device is equipped with a filter "G", located on the
cold water entrance. Periodically clean the hydraulic
system, if dirt is present.
¡IMPORTANT!
DO NOT ACTIVATE THE DEVICE WITHOUT
THE FILTER.
¡IMPORTANT!
IF THE UNIT IS INSTALLED IN AREAS
WITH THE PRESENCE OF HARD WATER
(> 200 MG / L) IS NECESSARY TO INSTALL
A WATER SOFTENER TO REDUCE THE
PRECIPITATION OF LIMESTONE IN THE
HEAT EXCHANGER.
THE WARRANTY DOES NOT COVER
DAMAGE CAUSED BY THE LIMESTONE.
Connection of flue gas discharge ducts
The appliance must be connected to a flue gas
discharge system that complies with the regulation in
force and instructions provided by the manufacturer.
WHEN TYPE B INSTALLATION IS USED, THE ROOM
IN WHICH THE APPLIANCE IS INSTALLED MUST BE
VENTILATED USING A SUITABLE AIR INLET WHICH
COMPLIES WITH CURRENT LEGISLATION.
When installing an exhaust system, take care of the
seals to prevent any flue gas leaking into the air circuit.
WARNING!!
NEVER TAMPER WITH OR DECOMMISSION
THE FLUE GAS SENSOR. THIS COULD
AFFECT THE PROPER OPERATION OF
THE APPLIANCE.
POOR DRAUGHT CONDITIONS COULD
CAUSE EXHAUST GAS BACKFLOW INTO
THE INSTALLATION ROOM.
HAZARD
OF
CARBON
INTOXICATION.
The part of flue pipe that pass through
the wall of dwelling should be surrounded
by insulated material (such as asbestos
cloth) at least 11 mm thickness and 300 mm
length since the temperature of flue pipe
maybe exceed the ambient temperature
by more than 60K.
installation
MONOXIDE
24