4 SOFTWARE FUNCTION DEFINITION
4.1
User Behavior Interaction
Note: Please refer to Configuration Parameter 0x51 for more details about Load Indicator Mode in the below table.
User behavior
Power OFF
Power ON
Click Action Button once
Click Action Button 2 times
quickly
Click Action Button 3 times
quickly
Press and hold Action Button
for [1, 2s)
AEOTEC Engineering Specification
Out of the Z-Wave network
Cut the power.
SmartStart Learn Mode:
Indicator Light will become flash white light
for 1s indicating the product has been
powered, and then become flash blue light
indicating SmartStart Learn Mode starts. It
will become constantly bright yellow light
after being assigned a NodeID.
If Adding succeeds, it will bright blue light
for 2s and become Load Indicator Mode.
If Adding fails, it will bright red light for 2s
and turn back to breathing blue light and
then start SmartStart Learn Mode again.
1.Send Node Info for Adding:
When click Action Button once, Indicator
Light will quickly flash blue light for 30s until
it is added into the network. It will become
constantly bright yellow light after being
assigned a NodeID.
If Adding succeeds, it will bright blue light
for 2s and become Load Indicator Mode.
If Adding fails, it will bright red light for 2s
and then become breathing blue light.
2.Exit Classic Inclusion Learn Mode :
If Action Button is clicked again during the
Classic Inclusion Learn Mode, the Learn
Mode will exit. At the same time, Indicator
Light will extinguish immediately, and then
become breathing blue light.
Reserved:
Indicator Light will become off when press,
and become breathing blue light when
release.
Reserved:
Indicator Light will become off when press,
and become breathing blue light when
release.
Reserved:
Indicator Light will become off when press,
and become breathing blue light when
release.
In the Z-Wave network
Cut the power.
Supply power:
Indicator Light will become flash white light
for 1s indicating the product has been
powered, and then become Load Indicator
Mode.
1.Toggle the switch state:
Indicator Light is closely related to the
configuration of Load Indicator Mode .
2.Exit testing communication quality:
If the product is triggered to testing
communication quality, it will exit when
click the Action Button once, and Indicator
Light will display the color according to the
communication quality, and then turn back
to Load Indicator Mode.
Send Node Info for Removing:
Indicator Light will become violet light for
up to 2s.
If Removing succeeds, it will become
breathing blue light.
If Removing fails, it will bright red light for
2s and then turn back to Load Indicator
Mode.
Disable the Alarm Response:
This function is related to the setting of
Configuration Parameter 10. If Parameter 10
is set to be 0, then when an enable alarm is
received,
response by 3x tapping Action Button within
1 second.
Reserved:
Indicator Light will become off when press,
and become breathing blue light when
release.
Page 5
user
can
disable
the