Parameter 80: To set which notification would be sent to the associated devices (Group 1)
To set which notification would be sent to the associated devices (Group 1) when the state of Nano Dimmers
load is changed.
Size: 1 Byte, Default Value: 0
Setting
0
1
2
3
4
Parameter 81: To set which notification would be sent to the associated nodes in association group 3
To set which notification would be sent to the associated nodes in association Group 3 when using the external
switch 1 to switch the loads.
Size: 1 Byte, Default Value: 1
Setting
0
1
Parameter 82: To set which notification would be sent to the associated nodes in association group 4
To set which notification would be sent to the associated nodes in association Group 4 when using the external
switch 2 to switch the loads.
Size: 1 Byte, Default Value: 1
Setting
0
1
Parameter 83: Configure the state of LED
Configure the state of LED when it is in 3 modes
Size: 1 Byte, Default Value: 0
Setting
0
256 - 316
2
Parameter 84: ON/OFF time
Set the ON/OFF time of the LED when it is in Night light mode.
Size: 4 Byte, Default Value: 524306
Setting
0 - 60
256 - 316
65536 - 65596
Description
Send Nothing
Send Hail CC
Send Basic CC report
Send Multilevel Switch report
Send Hail CC when using the manual switch to change the load state.
Description
Send Nothing
Send Basic Set CC
Description
Send Nothing
Send Basic Set CC
Description
The LED will follow the status (on/off) of its load (Energy mode).
The hour value of ON time
Night light mode.
Description
The minute time of OFF
The hour time of OFF
The minute time of ON