In addition, it is also possible to use a split system by fitting a special adapter to
the flue discharge collar and using one of the apertures for the air vent intake
located on the top part of the combustion chamber (A).
Ø 80 mm
Ø 80 mm
This procedure must be done as follows:
1 - Remove the air vent intake you want to use, in the area indicated in
Fig. 2.9, by breaking the perforated ring.
2 - Use a tool to grasp the lid and remove it completely.
3 - Clean any burrs or sharp edges with a knife or an appropriate tool.