Servicing Instructions
10.3

Access to the Combustion Chamber

10.3.1 Removing the combustion cover
1. Remove the screws "E" (F
2. Lift off the combustion cover.
E
E
10.3.2 Removing the burner and jets
1. Remove the screws "F" from the burner (F
2. Remove the burner (F
. 10.12);
IG
3. Disconnect the electrodes (see
4. Remove the jets using a No. 7 socket spanner;
5. Replace in reverse order.
F
. 10.11
IG
F
F
Fig. 10.12
Supplied By www.heating spares.co Tel. 0161 620 6677
. 10.10);
IG
E
E
F
. 10.10
IG
. 10.11);
IG
10.3.3);
SECTION
10.3.3 Removing the electrodes
Before carrying out this procedure, unscrew and slide the burn-
er forward (see previous section).
1. Remove rubber gasket "G" (F
2. To remove the detection electrode disconnect the cable at its
connection point close to the P.C.B. (F
3. Remove screw "H" (F
. 10.15);
IG
4. Gently slide the electrode downward (F
F
. 10.14
IG
F
. 10.16
IG
34
. 10.13);
IG
. 10.14);
IG
. 10.16).
IG
F
. 10.13
IG
G
F
. 10.15
IG
H
To replace, repeat the steps in
reverse order, paying particular
attention to the following:
a - Centre the electrode in the
positioning hole carefully,
otherwise the electrode may
break;
b - Ensure that the left hand and
right hand electrodes are
located the correct way
round (facing each other), to
give the correct spark gap;
c - Check that the cables have
been connected correctly;
d - Check that the rubber gasket
seals the cable/ electrode
connection point completely.