Ariston microCombi Anweisungen für die Wartung - Seite 5
Blättern Sie online oder laden Sie pdf Anweisungen für die Wartung für Boiler Ariston microCombi herunter. Ariston microCombi 28 Seiten. Type c boilers
Auch für Ariston microCombi: Installationsanleitung Handbuch (25 seiten)
1.3
A
CCESS TO THE
1.3.1 Removing the combustion cover
1. Remove the screws "E" (F
2. Lift off the combustion cover.
E
E
1.3.2 Removing the burner and jets
1. Remove the screws "F" from the burner (F
2. Remove the burner (F
IG
3. Disconnect the electrodes (see section 1.3.3);
4. Remove the jets using a No. 7 socket spanner;
5. Replace in reverse order.
F
. 1.11
IG
Supplied By www.heating spares.co Tel. 0161 620 6677
C
C
OMBUSTION
HAMBER
. 1.10);
IG
E
F
. 1.10
IG
. 1.11);
IG
. 1.12);
F
F
1.3.3 Removing the electrodes
Before carrying out this procedure, unscrew and slide the
burner forward (see previous section).
1. Remove rubber gasket "G" (F
2. To remove the detection electrode disconnect the cable
at its connection point close to the P.C.B. (F
3. Remove screw "H" (F
. 1.15);
IG
4. Gently slide the electrode downward (F
Fig. 1.12
. 1.13);
IG
. 1.14);
IG
. 1.16).
IG
F
. 1.13
IG
G
F
. 1.14
IG
5