Ariston microGENUS 23 MFFI Installationsanleitung Handbuch - Seite 9

Blättern Sie online oder laden Sie pdf Installationsanleitung Handbuch für Boiler Ariston microGENUS 23 MFFI herunter. Ariston microGENUS 23 MFFI 25 Seiten. Type c boilers
Auch für Ariston microGENUS 23 MFFI: Benutzerhandbuch (24 seiten), Anweisungen für die Wartung (28 seiten), Anweisungen für die Wartung (28 seiten)

Ariston microGENUS 23 MFFI Installationsanleitung Handbuch
2.9
F
C
LUE
ONNECTIONS
BC
F
D
J
HI
F
. 2.6
IG
Ø 60/100 mm
F
. 2.7
IG
F
LUE
The provision for satisfactory flue termination must be made as described
in BS 5440-1.
The appliance must be installed so that the flue terminal is exposed to outdoor air.
The terminal must not discharge into another room or space such as an
outhouse or lean-to.
It is important that the position of the terminal allows a free passage of air
across it at all times.
The terminal should be located with due regard for the damage or
discolouration that might occur on buildings in the vicinity.
In cold or humid weather water vapour may condense on leaving the flue
terminal.
The effect of such "steaming" must be considered.
If the terminal is less than 2 metres above a balcony, above ground or above
a flat roof to which people have access, then a suitable terminal guard must
be fitted. When ordering a terminal guard, quote the appliance model
number.
A suitable terminal guard is available from:
TOWER FLUE COMPONENTS
Morley Road
Tonbridge
Kent TN9 1RA
The minimum acceptable spacing from the terminal to obstructions and
ventilation openings are specified in F
F
G
A
E
K
L
G
FU010A
The boiler is designed to be connected to a coaxial flue discharge system.
FU025A
S
YSTEM
T
P
ERMINAL
OSTION
A - Directly below an open window or other opening
B - Below gutters, solid pipes or drain pipes
C - Below eaves
D - Below balconies or car-port roof
E - From vertical drain pipes and soil pipes
F - From internal or external corners
G - Above ground or below balcony level
H - From a surface facing a terminal
I - From a terminal facing a terminal
J - From an opening in the car port
(e.g. door, window) into dwelling
K - Vertically from a terminal in the same wall
L - Horizontally from a terminal in the same wall
9
. 2.6.
IG
mm
300
75
200
200
75
300
300
600
1200
1200
1500
300
FU002A