Aeotec ZWA039 Schnellstart-Handbuch - Seite 7

Blättern Sie online oder laden Sie pdf Schnellstart-Handbuch für Sicherheitssensoren Aeotec ZWA039 herunter. Aeotec ZWA039 12 Seiten. Temperature & humidity sensor

0
1 - 1000
Parameter 6: Temperature Lower Watermark value
This parameter defines a temperature. If the measured temperature drops below this watermark, a
BASIC command is sent into Association Group 3. The Sensor will check the watermark value for an
interval set by Parameter 16 or when the Sensor wakes up by button pressing.
Size: 2 Byte, Default Value: 0, Unit=0.1 degree
Setting
0
-200 - 1000
Parameter 7: Humidity Upper Watermark value
This parameter defines a relative humidity. If the measured relative humidity surpasses this watermark, a
BASIC command is sent into Association Group 4. The Sensor will check the watermark value for an
interval set by Parameter 16 or when the Sensor wakes up by button pressing.
Size: 1 Byte, Default Value: 0
Setting
0
1 - 90
Parameter 8: Humidity Lower Watermark value
This parameter defines a relative humidity. If the measured temperature drops below this relative
humidity a BASIC command is sent into Association Group 5. The Sensor will check the watermark value
for an interval set by Parameter 16 or when the Sensor wakes up by button pressing.
Size: 1 Byte, Default Value: 0
Setting
0
1 - 90
Parameter 9: Low Temperature Trigger BASIC Set Command Value
This defines what BASIC command shall be sent out into association group 3.
Size: 1 Byte, Default Value: 255
disabled
0.1-100 degree
Description
disabled
-20-100 degree
Description
disabled
1-90%
Description
disabled
1-90%