6.10 Shut down for prolonged periods
If the stove is to be left unused for a prolonged period of time then it should be given a
thorough clean to remove ash and unburned fuel residues. To enable a good flow of air
through the appliance to reduce condensation and subsequent damage, leave the air
controls fully open. It is important that the flue connection, any appliance baffles or
throat plates and the chimney are swept prior to lighting up after a prolonged shutdown
period.

6.11 Maintenance

Inspect the inside of the firebox and above the baffle plate every week during use.
Where the chimney is believed to have previously served an open fire installation, it is
possible that the higher flue gas temperature from the stove may loosen deposits that
were previously firmly adhered, with the consequent risk of flue blockage. It is therefore
recommended that the chimney be swept a second time within a month of regular use
after installation. See chimney cleaning section in section 3.1 Warnings and
Important Information. Inspect the inside of the stove and the flue ways and ensure
they are 100% clear after a period of disuse (e.g summer). Only use manufacturers
recommended replacement parts on the appliance

7.0 Safety Notes for your guidance

FIRES CAN BE DANGEROUS – Always use a fireguard to BS 8423:2002 Fireguards
for use with solid fuel appliances in the presence of children, the elderly or the infirm.
DO NOT perform modifications to the appliance as this could seriously
compromise safety in operation.
DO NOT OVERFIRE – it is possible to fire the stove beyond its design capacity, this
could damage the stove, so watch for signs of over firing – if any part of the stove starts
to glow red, including baffle plate or fuel retainer, the fire is in an over fire situation and
the controls should be adjusted accordingly. Never leave the stove unattended for long
periods without first adjusting the controls to a reduced and safe setting – careful air
supply control should be exercised at all times.
WARNING – FUME EMISSION
Properly installed and operated, this appliance will not emit fumes. Occasional fumes
from de-ashing and refuelling may occur which is not normally of serious concern.
However, persistent fume emission is potentially dangerous and must not be
tolerated.
If fume emission does persist, then the following immediate action should be taken: -
1.
Open doors and windows to ventilate room
2.
Let the fire out, or remove and safely dispose of fuel from the appliance.
3.
Check for flue chimney blockage and clean if required.
4.
Do not attempt to re-light the fire until the cause has been identified and
corrected.
If necessary, seek professional advice from chimney or stove specialists.
Important! – Do not fit an extractor fan in the same room as this appliance.
IN THE EVENT OF A CHIMNEY FIRE
Raise the alarm to let others in the house know.
Call the Fire Service
FXiT.FPiT.FGiT
12
Issue 02 10/12