Ariston AS700C Gebrauchsanweisung - Seite 10

Blättern Sie online oder laden Sie pdf Gebrauchsanweisung für Trockner Ariston AS700C herunter. Ariston AS700C 36 Seiten.

Ariston AS700C Gebrauchsanweisung

Maintenance and Care

Switching off the electricity

GB
! Unplug your dryer when not using it, when cleaning
it and during all maintenance operations.
Clean the filter after each cycle
The filter is an important part of your dryer:
it accumulates lint and fluff that is formed while drying.
When finished drying, clean the filter by rinsing it
under running water or with your vacuum cleaner.
Should the filter become clogged up, the airflow inside
the dryer will be seriously compromised: drying times
lengthen and you will consume more energy. It may
also damage your dryer.
The filter is found in front of the dryer trim (see diagram).
Removing the filter:
1. Pull the plastic grip of the filter upwards (see diagram).
2. Clean the filter and replace it correctly.
Ensure the filter is fully located flush into the tumble
dryer trim.
! Do not use the dryer without replacing the filter.
Empty the water container after each
cycle
Pull the container out of the dryer and empty it into a
sink or other suitable drain.
Replace the water container securely.
Always check and empty the container before you
start a new drying programme.

Check the drum after each cycle

Turn the drum manually in order to remove small items
(handkerchiefs) that could have been left behind.
Water container
Condenser unit
Condenser cover
10
Filter
Catches
Handle
Cleaning the drum
! Do not use abrasives, steel wool or stainless steel
cleaning agents to clean the drum.
A coloured film may start to appear on the stainless
steel drum, this may be caused by a combination of
water and, or cleaning agents such as fabric conditioner
from the wash. This coloured film will not affect the
dryer performance.

Cleaning the condenser unit

Periodically (every month) remove the condenser unit
and clean any build up of fluff from between the plates
by rinsing it under the tap with cold water.
This should be done with cold water from the rear of
the condenser.
Removing the condenser:
1. Unplug the dryer and open the door.
2. Pull open the condenser cover (see diagram).
Release the three catches by turning 90˚ counter-
clockwise then pull on the grip and remove from
the dryer.
3. Clean the surface of the seals and replace, making
sure that the catches have been secured.

Cleaning the dryer

External parts in metal or plastic and rubber parts
can be cleaned with a damp cloth.
Periodically (every 6 months) vacuum the front air
intake grille and vents at the rear of the dryer, to
remove any build up of fluff, lint or dust. Also to
remove accumulation of fluff from the front of the
condenser and filter areas, clean occasionally with
a vacuum cleaner.
! Do not use solvents or abrasives.
! Your dryer uses special bearing components which
do not need lubrication.
! Have your dryer checked regularly by authorised
technicians to ensure electrical and mechanical safety
(see Service).
Tap
Front
Air intake
Condenser unit
Rear