2. INSTALLATION RESPONSIBILITIES

WARNING: THE APPLIANCE AND FLUE SYSTEM SHALL BE INSTALLED
IN ACCORDANCE WITH AS/NZ 2918:2001 AND THE APPROPRIATE
REQUIREMENTS OF THE RELEVANT BUILDING CODE OR CODES.
ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN
APPROVED IN WRITING BY THE TESTING AUTHORITY IS CONSIDERED
TO BE IN BREACH OF THE APPROVAL GRANTED FOR COMPLIANCE
WITH AS/NZS 4013.
CAUTION: MIXING OF APPLIANCE OR FLUE-SYSTEM COMPONENTS FROM
DIFFERENT SOURCES OR MODIFYING THE DIMENSIONAL SPECIFICATION OF
COMPONENTS MAY RESULT IN HAZARDOUS CONDITIONS. WHERE SUCH ACTION
IS CONSIDERED, THE MANUFACTURER SHOULD BE CONSULTED IN THE FIRST
INSTANCE.
Strict adherence to these instructions will meet these standards.
Any variation from these installation instructions or any doubt about them must be
checked against the requirements of the Standards.
WARNING:
Care must be taken to protect the wetback coil and associated pipe work if being installed in a
hard/corrosive water area. Damage caused to the Wetback coil if fitted in a hard/corrosive water
area will not be covered under the manufacturer's warranty.
Please leave this manual with the owner when installation is complete.

3. FLOOR PROTECTOR REQUIREMENTS

The heater should always be installed on top of its base due to high temperatures
sustained over long periods. The base must be anchored to both the floor protector and the floor
for seismic restraint. Anchor points are provided in the base or on the rear legs.
DRAWER BASE AND PEDESTAL MODELS:
insulated floor
If the heater is to be placed on or within 500mm of a heat sensitive floor, an
protector
40mm
with a minimum thickness of
is required consisting of 20mm of an
approved insulation material i.e. 2 sheets of 10mm micorboard or superlux, 10mm tile backing
board and 10mm tiles or similar on the top surface. All joints on the upper surface should be
sealed to prevent spilt ash from contacting any heat-sensitive material.
LEG BASE MODELS:
These models require an ash floor protector to AS/NZS 2918:2001 – i.e. a floor protector
consisting of an upper surface, including grouting, of a durable, non-combustible material.
3