Whirlpool 240-VOLT ELECTRIC DRYER Handbuch für Gebrauch und Pflege - Seite 10
Blättern Sie online oder laden Sie pdf Handbuch für Gebrauch und Pflege für Trockner Whirlpool 240-VOLT ELECTRIC DRYER herunter. Whirlpool 240-VOLT ELECTRIC DRYER 24 Seiten. 240-volt electric dryer
Auch für Whirlpool 240-VOLT ELECTRIC DRYER: Handbuch für Gebrauch und Pflege (20 seiten), Handbuch für Gebrauch und Pflege (33 seiten), Handbuch für Gebrauch und Pflege (24 seiten), Handbuch für Gebrauch und Pflege (32 seiten)
3. Connect ground wire (green or bare) of power supply cable to
external ground conductor screw. Tighten screw.
A
F
E
D
A. External ground conductor screw
B. Center silver-colored terminal block screw
C. Neutral wire (white or center wire)
D. ¾" (1.9 cm) UL listed strain relief
E. Neutral ground wire
F. Ground wire (green or bare) of power supply cable
4. Place the hooked ends of the other power supply cable wires
under the outer terminal block screws (hooks facing right).
Squeeze hooked ends together. Tighten screws.
5. Tighten strain relief screws.
6. Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.
7. You have completed your electrical connections. Now go to
"Venting Requirements."
3-wire connection: Power Supply Cord
Use where local codes permit connecting cabinet-ground
conductor to neutral wire:
B
A
C
A. 3-wire receptacle (NEMA type 10-30R)
B. 3-wire plug
C. Neutral prong
D. Spade terminals with up turned ends
E. " (1.9 cm) UL listed strain relief
F. Ring terminals
G. Neutral (white or center wire)
10
B
C
E
D
F
G
1. Loosen or remove center silver-colored terminal block screw.
2. Connect neutral wire (white or center wire) of power supply
cord to the center, silver-colored terminal screw of the
terminal block. Tighten screw.
B
A
A. Neutral ground wire
B. External ground conductor screw
C. Center silver-colored terminal block screw
D. Neutral wire (white or center wire)
E. " (1.9 cm) UL listed strain relief
3. Connect the other wires to outer terminal block screws.
Tighten screws.
4. Tighten strain relief screws.
5. Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.
6. You have completed your electrical connections. Now go to
"Venting Requirements."
3-wire connection: Direct Wire
Use where local codes permit connecting cabinet-ground
conductor to neutral wire.
Direct wire cable must have 5 ft (1.52 m) of extra length so dryer
can be moved if needed.
Strip 3 " (8.9 cm) of outer covering from end of cable. Strip
insulation back 1" (2.5 cm). If using 3-wire cable with ground
wire, cut bare wire even with outer covering. Bend ends of wires
into a hook shape.
When connecting to the terminal block, place the hooked end of
the wire under the screw of the terminal block (hook facing right),
squeeze hooked end together and tighten screw, as shown.
C
D
E