Whirlpool Cabrio WGD6200S Handbuch für Gebrauch und Pflege - Seite 7

Blättern Sie online oder laden Sie pdf Handbuch für Gebrauch und Pflege für Trockner Whirlpool Cabrio WGD6200S herunter. Whirlpool Cabrio WGD6200S 48 Seiten. Gas dryer
Auch für Whirlpool Cabrio WGD6200S: Abmessungen und Installationsinformationen (1 seiten), Produktabmessungen (1 seiten)

Whirlpool Cabrio WGD6200S Handbuch für Gebrauch und Pflege
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure
gas pressure does not exceed 13" (33 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
Gas Type
Natural Gas:
This dryer is equipped for use with Natural gas. It is design-
certified by CSA International for LP (propane or butane) gases
with appropriate conversion.
Your dryer must have the correct burner for the type of gas in
your home. Burner information is located on the rating plate
in the door well of your dryer. If this information does not
agree with the type of gas available, contact your dealer or
call the phone numbers referenced on the front page of this
manual.
LP gas conversion:
Conversion must be made by a qualified technician.
No attempt shall be made to convert the appliance from the gas
specified on the model/serial rating plate for use with a different
gas without consulting your gas company. For information on
ordering an LP conversion kit, please refer to the "Assistance or
Service" section. Ask for Part Number 49572.
Gas Supply Line:
Must include
" NPT minimum plugged tapping accessible
for test gauge connection, immediately upstream of the gas
connection to the dryer (see illustration).
" IPS pipe is recommended.
" approved aluminum or copper tubing is acceptable for
lengths under 20 ft (6.1 m) if local codes and gas supplier
permit.
If you are using Natural gas, do not use copper tubing.

Gas Supply Requirements

" flare x
approved tubing.
Lengths over 20 ft (6.1 m) should use larger tubing and a
different size adapter fitting.
If your dryer has been converted to use LP gas,
compatible copper tubing can be used. If the total length of
the supply line is more than 20 ft (6.1 m), use larger pipe.
NOTE: Pipe-joint compounds that resist the action of LP gas
must be used. Do not use TEFLON
Must include a shutoff valve:
In the U.S.A.:
An individual manual shutoff valve must be installed within
six (6) feet (1.8 m) of the dryer in accordance with the National
Fuel Gas Code, ANSI Z223.1.
In Canada:
An individual manual shutoff valve must be installed in
accordance with the B149.1, Natural Gas and Propane
Installation Code. It is recommended that an individual
manual shutoff valve be installed within six (6) feet (1.8 m) of
the dryer.
The location should be easy to reach for opening and closing.
Gas supply connection requirements
Use an elbow and a
between the flexible gas connector and the dryer gas pipe, as
needed to avoid kinking.
Use only pipe-joint compound. Do not use TEFLON
This dryer must be connected to the gas supply line with a
listed flexible gas connector that complies with the standard
for connectors for gas appliances, ANSI Z21.24 or CSA 6.10.
®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.
" NPT adapter fitting between dryer pipe and
®†
tape.
A
C
E
B
A. " flexible gas connector
B. " pipe to flare adapter fitting
C. " NPT minimum plugged tapping
D. ½" NPT gas supply line
E. Gas shutoff valve
" flare x
" NPT adapter fitting
"
" LP
D
®†
tape.
7