Whirlpool DryAire LMA1053LT Handbuch - Seite 26

Blättern Sie online oder laden Sie pdf Handbuch für Trockner Whirlpool DryAire LMA1053LT herunter. Whirlpool DryAire LMA1053LT 32 Seiten. Drying cabinet

Whirlpool DryAire LMA1053LT Handbuch
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.

FAN MOTOR

Refer to page 4-5 for the procedure for servic-
ing the blower assembly.
1.
Disconnect the power to the drying cabi-
net.
2.
Disconnect one of the wires from the fan
motor terminals.
3.
Set the ohmmeter to the R x 1 scale.
4.
Touch the ohmmeter leads to the fan
motor terminals. The meter should indi-
cate between 8 and 16 Ω.
WARNING
Electrical Shock Hazard
Fan Motor Terminals
5-2

THERMOSTAT

Refer to page 4-5 for the procedure for servic-
ing the thermostat.
1.
Disconnect the power to the drying cabi-
net.
2.
Disconnect the wire from one of the ther-
mostat terminals.
3.
Turn the thermostat to 0 (off).
4.
Set the ohmmeter to the R x 1 scale.
5.
Touch the ohmmeter leads to the thermo-
stat terminals. The meter should indicate
an open (infinite) circuit.
6.
Turn the thermostat knob clockwise until
you hear it click.
7.
Touch the ohmmeter leads to the thermo-
stat terminals. The meter should indicate a
closed circuit (0 Ω).
Thermostat
Terminals