Whirlpool ELECTRIC DRYER Installationsanleitung Handbuch - Seite 3

Blättern Sie online oder laden Sie pdf Installationsanleitung Handbuch für Trockner Whirlpool ELECTRIC DRYER herunter. Whirlpool ELECTRIC DRYER 6 Seiten. Electric dryer
Auch für Whirlpool ELECTRIC DRYER: Handbuch für Gebrauch und Pflege (20 seiten), Handbuch für Gebrauch und Pflege (28 seiten), Einbauanleitung (5 seiten), Handbuch für Gebrauch und Pflege (23 seiten), Installationsanleitung Handbuch (7 seiten)

Whirlpool ELECTRIC DRYER Installationsanleitung Handbuch
5. Exhaust
outlet
at rear of dryer
IS located
as shown
In
Figure
4. Detailed
instructions
on spacing
for side
and
rear
clearances
can be found
In the sectlon
"Recessed
and Closet
Instructions."
Also
mInImum
spacing
to side
and rear information
is located
on a separate
label
(found
on rear panel).
13. We do NOT RECOMMEND
non-metalllc
flexible
duct.
If you use non-metallic
flexible
duct
you must
connect
a
METAL
elbow
and at least
2 feet of METAL
duct
to the
dryer
outlet.
The length
of the non-metallic
flexible
duct
should
not
exceed
7 feet,
and
It must
be adequately
supported
to prevent
sagging
or klnking
See FIG. 6.
?ypical
E%hauSt Installations
11.15/16"
4"
DIA
d&&l
---/.
t
3.5132"
Figure 4
6. If you wish
IO permanently
install
the portable
dryer,
a
stationary
exhaust
system
is recommended.
7. We strongly
recommend
exhausting
with 4 inch dlame-
ter rigid
METAL
duct.
We strongly
recommend
METAL
flexible
duct
if you
use
flexible
duct.
NEVER
USE
SMALLER
THAN
4 INCH EXHAUST
DUCT.
8.The
exhaust
may
be routed
up, down,
left.
right
or
straight
through
the wall.
9. The exhaust
duct should
terminate
with an exhaust
hood to prevent
back drafts. The outlet of the hood must
be at least 12 inches from the ground or any obstruction.
An exhaust hood with a 4 inch outlet is preferred
because
it creates
less back pressure.
A louvered
exhaust
hood
for 4 inch duct is also recommended.
An exhaust
hood
with a
2'12
inch outlet creates
more back pressure,
but
may be Lised with shorter systems. Never use an exhaust
hood with a magnetic
latch.
lO.The maximum
length of the exhaust
system depends
upon the type of duct used, the number of elbows and the
type of exhaust
hood. The maximum
length for both rigid
and flexible
duct is shown in the chart, FIG. 5.
EXHAUST
HOOD
TYPE
:Y,",'::'
p--&@
gb-
MAXIMUM
0
43 Fr.
41 FT.
36 FT.
LENGTH
OF
1
33 Fr.
31 Fr.
26 FT.
4- DIA.
2
23 FT.
21 FT.
16 FT.
RIGID
METAL
DUCT.
MAXIMUM
0
30 FT.
29 FT.
24 FT.
LENGTH
OF
1
24 FT.
23 IT.
16 FT.
4' DIA
2
16Fl.
15Ff.
10 FT.
FLEXIBLE
METAL
DUCT.
L
Figure 5
11. Use duct tape to seal
all
joints. Never use screws
to
assemble
the ductwork,
screws
can catch
lint.
12. Exhaust
systems
longer
than
specified
will
shorten
the life of the dryer
and result
in reduction
of perform-
ance such as longer
drying
time
and
increased
use of
energy.
Lint may also accumulate
creating
a possible
safety
hazard.The
exhaust
system
must be cleaned
Periodically,
at least every
two years.
EXHAUST
HOOD
'1
J
RECOMMENDED
IMPORTANT:
PROPER
SUPPORT
IS REOUIRED
I
-
-
.
.
-
,
.
.
DUCTING
NOT
T
EXCEC"
7 C.zCT
ALTERNATE
Figure 6
NEVER INSTALL ANY TYPE OF FLEXIBLE
DUCT CON-
CEALED IN WALLS OR CEILING
14. There are exhaust
kits aizlable
that allow the filtered
exhaust
air to be directed
inside
to conserve
energy
during
winter
months.
Some of these kits cause restric-
tions or excessive
back pressure
and must NOT be used.
In some locations
exhaust
moisture
may cause building
damage.
If you use one of these kits you must maintain
it
properly
to avoid excessive
lint build up which results in
reduced
dryer performance.
For continued
proper opera-
tion the exhaust
duct should
be inspected
periodically,
depending
on use. Inspection
and cleaning
will help
prevent
blockage
of the exhaust
system,
reduced
air
flow
and long drying
time.
After
inspection
be sure
to
reconnect
the
exhaust
system
properly,
using
duct tape to fasten the joints.
15.Leveling
feet (Part No. 233550) for use in permanent
installations
are available
at your Whirlpool
dealer. Four
feet are required.
The feet should extend about 1" below
the bottom
of the dryer.
16. If you do not desire to install
a permanent
exhaust
system,
you may purchase
a Window
Exhaust
Kit (No.
LCK3000)
from your WHIRLPOOL
dealer.
The Window
Exhaust
Kit is designed
to exhaust
the dryer out of a
double
hung
window.
Complete
instructions
are in-
cluded with the kit.
17. For mobile
home
installations
the dryer
must
be
exhausted
to the outside.
If the dryer
is exhausted
through
the floor
and the area
under the mobile home is
enclosed,
the exhaust
system
must terminate
outside
the enclosure.
Extension
beyond
the enclosure
will
prevent
the accumulation
of lint and moisture
under
the mobile
home.
See Figure
7.
3