The console
houses the electronic
control
board,
The board
is factory
set for a dry time of 45 minutes,
Consult the tech sheet found inside
the dryer toe panel
to reset dry time
and for other options,
The coin-slide
mechanism,
control
panel
lock and key, and coin-box
lock and key are not included
and
are available
from usual industry
sources,
IMPORTANT SETUP INFORMATION
The electronic
control
is factory
preset to accept
commands
from a
Palm®handhold
equipped
with the
appropriate
Whirlpool
management
software,
If a handheld
is not to be
used, the handhold
functionality
MUST BE DISABLED as part of the
control
set up, Failure to disable
handhold
functionality
may result in
unauthorized
machine
access,
Exhaust
requirements
Fire Hazard
Use a heavy metal vent.
Do not use a plastic vent.
Do not use a metal foil vent.
Failure to do so can result in
death or fire,
Do not use non-metal
flexible vent,
metal vent that is smaller than four
inches in diameter
or exhaust hoods
with magnetic
latches,
The dryer must be exhausted
outdoors.
Do not exhaust dryer into a gas vent,
chimney,
wall, ceiling,
or concealed
space
of a building,
Do not install flexible vent in enclosed
walls, ceilings or floors,
If using an existing exhaust system,
clean
lint from entire length of exhaust
system, Make sure exhaust hood is not
plugged
with lint,
The exhaust system should be
inspected
and cleaned
yearly,
Replace
any plastic or metal foil
exhaust vent with rigid metal
or flexible
metal vent,
Use 4" (10,2 cm) vent clamps to
secure vent system,
exhaust airflow
beffer
[==] good
P]
Four-inch (10.2 cm) metal exhaust vent
isrequired,
Plan installation to use the
fewest
number
of elbows and turns,
Metal flexible vent must be fully
extended
and supported
when the
dryer is in its final position,
DO NOT
KINK OR CRUSH THE VENT, The metal
flexible vent must be completely
open to allow adequate
exhaust air
to flow.
Allow as much
room as possible
when using elbows or making turns,
Bend vent gradually
to avoid kinking,
Remove
excess flexible vent to avoid
sagging
and kinking that may result in
reduced
air flow,
Exhaust outlet is located
at the
center
of the bottom
dryer back,
The exhaust vent can be routed up,
down,
left, right, behind
the dryer or
straight
out the back of the dryer,
Maximum
length of exhaust
system
depends
upon the type of vent used,
number
of elbows and type of
exhaust
hood, The maximum
length
for both rigid and flexible vent is
shown in the chart,
EXHAUSTHOOD TYPE
r
4 •
(10.2 cm)
10.2 cm)
turns
_ y
MAI_MUMLE_I_lltOF 4-1N_'t
RIGID METAL t _NT
10.2 _
DIAMEI_R
8
64 FT. 1 19.5ml
64 FT. (19.5ml
58 FT. 117.7 r_
1
54 FT. (16.5 m)
54 FT.116.5 m)
48 FT.(14_ n0
2
44 FT. (13.4 rn]
44 FT.(13.4 rn]
38 FT.(11_ n0
3
36 FT. (10.7 m)
36 FT.(I0.7 m)
29 FT.(8.8 m]
4
27 FT. (8.2 m)
27 FT.(8.2 m)
21 FT.(5.4 m)
MAXIMUM LEN@111 OF4-1NCH(I 0.2 cm) DIAMb'IIE R
FL_BLEMETAL VENT
O
36 FT.(11.0 m)
36 FT.(11.0 m)
28 FT.(8_ m)
I
31 FT.(gA m)
31 FT.(9.4 m)
23 FT.(7_ m)
2
27 FT.(8.2 n0
27 FT.(8.2 m)
19 FT.(6Ji m]
3
25 FT.(7_ rn)
26 FT.(7.6 m]
17 FT.(6.2 m]
4
23 FT.(7.On0
23 FT.(7.0 m]
15 FT.(4_ m]
For exhaust systems not covered
by
the exhaust
length chart, see
Whirlpool
Service Manual,
"Exhausting
Whirlpool
Dryers," Part No, 603197,
available
from your Whirlpool
parts
distributor,
If dryer is installed in a confined area,
such as a bedroom,
bathroom or
closet, it must be exhausted
to the
outside and provision
made for
enough
air for combustion
and
ventilation,
(Check
governing
codes
and ordinances,)
See "Recessed
area
and closet installation
instructions"
on
Page 12,