FirePro FP240V Benutzerhandbuch - Seite 4
Blättern Sie online oder laden Sie pdf Benutzerhandbuch für Rauchmelder FirePro FP240V herunter. FirePro FP240V 8 Seiten. Photoelectric ac220~240v with 9v dc battery backup smoke alarm.
- 1. Important Safety Information
- 2. Battery Specification
- 3. Replace Battery
- 4. Operation
- 5. Led Indicators
- 6. Troubleshooting
- 7. Maintenance and Cleaning
- 8. Develop and Practice a Plan of Escape
- 9. What to Do When the Alarm Sounds
- 10. Recommended Locations for Alarms
- 11. Mounting Instructions
- 12. Wiring Instructions
- 13. Installation Sketch Map
- 14. Service and Warranty
If the alarm is no longer under warranty, replace it
immediately with a comparable alarm.
Trouble shooting:
Problem
1.Check
The green LED does
not light when AC
2.If the problem still exists, please
power supply.
3.If the unit is out of warranty,
1.Ensure
Smoke alarm does not
sound when tested.
2. Clean smoke alarm.
NOTE:
Push
test
3. If there are still failures during
button for at least five
warranty, you can return to your
seconds while testing!
retailer.
4. If the unit is out of warranty ,
please replace another new alarm
The
alarm
chirp
occurs
every about
The battery is in low battery status,
approx 32 seconds, at
please replace battery, and refer to
the same time as the
"replace battery" section.
red LED flash once
Smoke alarm chirp
1.Clean smoke alarm. Please refer to
occurs every approx
32 seconds ( alarm
goes into fault mode) .
Smoke alarm sounds
1.Press test button to pause alarm.
unwanted
alarms
2. Clean smoke alarm device. Please
intermittently
or
when residents are
cooking,
taking
3. Move smoke alarm device to new
showers, etc.
1.Clean smoke alarm device. Please
The
alarm
sounds
refer to the "maintenance and
different from it is
cleaning" section.
used to. It starts and
2.If there are still failures during
stops.
warranty, you can return to your
retailer.
3. if the unit is out of warranty ,
please replace another new alarm.
WARNING: Do not disconnect battery to quiet an unwanted
alarm. This will remove your protection. Fan the air or open a
Document NO.:RD-517E-39-001
Cause and Remedy
the
AC
CONNECTOR is properly connect
to the smoke alarm.
return to your retailer.
please replace another new alarm.
that
the
battery
the AC QUICK CONNECTOR is
properly connected.
the "maintenance and cleaning"
section.
2.Purchase and change another
smoke alarm if the problem still
exist
refer to the "maintenance and
cleaning" section.
location and press test button.
window to remove smoke or dust.
Maintenance and Cleaning:
In addition to weekly testing, cleaning to remove dust, dirt,
and debris at least once a month. Always turn off the power
QUICK
before cleaning.
Use a vacuum cleaner with the soft brush, vacuum all sides
and covers of smoke alarm. Be sure all the vents are free of
debris. Use a damp cloth to clean the alarm's cover.
This smoke alarm uses a 9 volt battery. A fresh battery should
last for at least one year under normal operate conditions.
This alarm has a low battery monitor which will cause the
and
alarm to "chirp" and at the same time as the red LED flash
approx every 32 seconds for a minimum of thirty days when
the battery gets low. Replace the battery when this condition
occurs. Please refer to "REPLACE BATTERY".
IMPORTANT: Do not attempt to remove the cover to clean
inside. This will affect warranty.
Develop and Practice a Plan of Escape:
• Install and maintain fire extinguishers on every level of the
home and in the basement and garage. Know how to use a
fire extinguisher prior to an emergency.
• Make a floor plan indicating all doors and windows and at
least two escape routes from each room. Second story
windows may need a rope or chain ladder.
• Have a family meeting and discuss your escape plan,
showing everyone what to do in case of fire.
• Determine a place outside your home where you all can
meet if a fire occurs.
• Familiarize everyone with the sound of the smoke alarm
and train them to leave your home when they hear it.
• Teach all household members to touch the door and use an
alternate exit when the door is hot, instruct them not to
open the door if the door is hot.
• Teach household members to crawl along the floor to stay
below dangerous smoke, fumes and gases.
.
• Practice a fire drill at least every six months, including fire
drills at night. Ensure that small children hear the alarm
and wake when it sounds. They must wake up in order to
execute the escape plan. Practice allows all occupants to
test your plan before an emergency. You may not be able to
reach your children. It is important they know what to do.
• Current studies have shown smoke alarms may not awaken
all sleeping individuals, and that it is the responsibility of
individuals in the household that are capable of
others to provide assistance to those who may not be
awakened by the alarm sound, or to those who may be
- 4 -
assisting
Version: D 2017.04.28