Install Range Hood

WARNING
Excessive Weight Hazard
Use two or more people to move and install range hood.
Failure to do so can result in back or other injury.
1. Hang hood on 2 mounting hooks through the rectangular
cutouts on back of hood.
A
D
B
A, Mounting hooks
B. Mounting screws
C. Leveling screws
D. Centerline on wall
2. Level the hood with leveling screws in mounting hooks or
rectangular cutouts, using a level across bottom of hood.
3. Secure hood with 4 screws through remaining 4 holes in hood.

Install Vent (for vented installations only)

1. Fit vent system over transition piece.
A. Transition
2. Seal connection with duct tape.
8
B
C
A

Make Electrical Connection

WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
1. Disconnect power.
2. Remove terminal box cover.
3. Remove the knockout in terminal box cover and install the
UL-or CSA-listed
" conduit.
4. Run 3 wires, black, white and green (14AWG) in
from service panel to terminal box.
5. Use twist-on connectors and connect black wires together.
6. Use twist-on connectors and connect white wires together.
WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire
in terminal box.
Failure to do so can result in death or electrical shock.
7. Use twist-on connectors and connect green or bare wire with
yellow-green wire.
8. Replace terminal box cover.
9. Check all light bulbs to make sure they are secure in their
sockets.
10. Reconnect power.
" conduit
A
A. Conduit