3.
To wire through
wall:
Mark a line distance "A" from the right of the centerline on the
underside of the wall. Mark the point on this line that is 3/4"
(1.9 cm) from the underside of the cabinet. Drill a
1V4" (3.2 cm) diameter hole through the rear wall at this point.
Centerline
A. 107/8 ' ' (27.6 cm)
Style 1 - Cut Openings
for 31/4'' x 10" (8.3 cm x 25.4 cm)
Rectangular
Vent System
Roof Venting
To make a 41/4'' x 101/2 '' (10.8 cm x 26.7 cm) rectangular cutout
on the underside of cabinet top and bottom:
1. Mark lines 1/2"(1.3 cm) and 43/4"(12.1 cm) from the back wall
on the centerline of the underside of cabinet.
2. Mark lines 51¼'' (13.3 cm) to the right and left of the centerline
on the underside of cabinet.
3. Use saber or keyhole saw to cut a rectangular opening for
vent.
4. Repeat steps 1-3 for the underside of the top of the cabinet.
......................................
* "
crn)
•From wall, not cabinet frame
Wall Venting
To make a 31/2'' x 101/2 '' (8.9 cm x 26.7 cm) rectangle in the
wall:
1. Make 2 lines by measuring 3/8"(0.9 cm) and 37/8"(9.8 cm)
down from underside of cabinet and mark on the centerline
on the back wall.
2. Mark lines 51¼"(13.3 cm) to the right and left of the centerline
on the wall.
3. Use saber or keyhole saw to cut a rectangular opening in the
wall for the vent.
/
Centerline
I
Cabinet
I/
L
front
,___
-'T"__---
37/8 ''
i _'_& 5W'
(9.8
ore)
i
(13.3
ore)
Style 2 - Cut Openings for 31/4'' x 10" (8.3 x 25.4 cm)
Rectangular
Vent to Round Vent Transition
Roof Venting
To make a 41/4 '' x 101/2 '' (10.8 cm x 26.7 cm) rectangular cutout
on the underside of cabinet bottom:
1. Mark lines 1/2"(1.3 cm) and 43/4"(12.1 cm) from the back wall
on the centerline of the underside of cabinet.
2. Mark lines 51¼ '' (13.3 cm) to the right and left of the centerline
on the underside of cabinet.
3. Use saber or keyhole saw to cut a rectangular opening for
vent.
*From wall, not cabinet frame
To make a circular vent opening on the underside of the
cabinet top:
1. Mark a centerline on the underside of the top of cabinet.
2. Mark a line 5" (12.7 cm) from the back wall on the underside
of the top of cabinet.
3. Use a compass or a circle template to draw a circle with a
diameter that is 1¼,, ( 0.64 cm) larger than the vent.
4. Use saber or keyhole saw to cut the circular vent opening.
Circular
vent opening
'il
*From wall, not
cabinet frame
/
Cabinet
cutouts