PRODUCT MODEL NUMBERS
GZ7730X
GZ7736X
Electrical: 120-volt, 60-Hz, AC-only, 15-amp.
electrical supply. Use copper wire only. A time-
delay fuse or circuit breaker and separate circuit
is recommended.
VENTING REQUIREMENTS
3-1/4" x 10"
(8.3 cm x 25 cm)
vent through
the roof
Roof venting
Recommended
standard fittings
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
30" and 36" Slide-out Vent System
OVERALL DIMENSIONS
FRONT OF
VENT HOOD
9-1/2"
(24.1 cm)
glass shelf
extends
7" (17.8 cm)
1"
(25.4 mm)
9-1/8"
(23.2 cm)
11"
(27.9 cm)
3-1/4" x 10"
(8.3 cm x 25 cm)
vent through
the wall
Wall venting
3-1/4" x 10"
(8.3 cm x 25 cm)
90° elbow
= 5 ft. (1.5 m)
3-1/4" x 10"
(8.3 cm x 25 cm)
flat elbow
= 12 ft. (3.7 m)
3-1/4" x 10"
(8.3 cm x 25 cm)
wall cap
= 0 ft. (0 m)
30" (76.2 cm) model: 8" (20.3 cm)
36" (91.4 cm) model: 11" (27.9 cm)
30" (76.2 cm) model: 26" (66.0 cm)
36" (91.4 cm) model: 32" (81.3 cm)
10"
(25.4 cm)
2-3/8"
(6.0 cm)
2"
(5.1 cm)
8"
(20.3 cm)
1-1/4"
1-5/8"
(31.8 mm)
(41.3 mm)
5/8" to 2-1/8"
(1.6 cm to 5.4 cm)
(5.1 cm)
1-7/16"
(3.6 cm)
Recommended vent system length
Use 3 1/4" x 10" (8.3 cm x 25 cm) vent with maximum length of
26 feet (8 m) for vent system. For best performance, use no more
than three 90° elbows. To calculate the length of system you need,
add the equivalent feet (meters) for each vent piece used in the
system. See the following example.
wall
cap
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
4-3/8"
(11.1 cm)
30" (76.2 cm) model: 13" (33.0 cm)
36" (91.4 cm) model: 16" (40.6 cm)
1/4"
(6.4 mm)
30" (76.2 cm) model: 29-7/8" (75.9 cm)
36" (91.4 cm) model: 35-7/8" (91.1 cm)
2"
66" (167.6 cm) maximum distance from upper
cabinet hood mounting surface to floor
24" (61 cm) minimum distance from underside
of range hood to cooking surface or countertop
15" (38.1 cm) minimum upper cabinet height
13" (33 cm) upper cabinet depth
3-1/4" x 10" (8.3 cm x 25 cm)
vent system
3-1/4" x 10"
(8.3 cm x 25 cm)
90° elbow
6 ft. (1.8 m)
3 ft.
(0.93 m)
Maximum length
= 26 ft.
1 — 90° elbow
= 5 ft. (1.5 m)
9 ft. (2.8 m) straight
= 9 ft. (2.8 m)
1 — wall cap
= 0 ft.
Length of 3-1/4" x 10"
(8.3 cm x 25 cm)
system
= 14 ft. (4.3 m)
3-1/4" (8.3 cm)
3/8" (9.5 mm)
BACK OF
VENT HOOD
wall
cap
(8 m)
(0 m)
Ref. 4360365 Rev. C