Whirlpool GZ8330 Series and Installationsanleitung und Gebrauchs- und Pflegeanleitung - Seite 4

Blättern Sie online oder laden Sie pdf Installationsanleitung und Gebrauchs- und Pflegeanleitung für Lüftungshaube Whirlpool GZ8330 Series and herunter. Whirlpool GZ8330 Series and 20 Seiten. 30" and 36" convertible range hood
Auch für Whirlpool GZ8330 Series and: Installationsanweisungen und Gebrauchs- und Pflegeanleitung (10 seiten)

Whirlpool GZ8330 Series and Installationsanleitung und Gebrauchs- und Pflegeanleitung
3-1/4" x 10" (8.3 x 25.4 cm) vent system
3-1/4" x 10"
(8.3 x 25.4 cm)
elbow
6 ft. ( 1.8 m)
2 ft.
(0.6 m)
Recommended standard fittings
3-1/4" x 10"
(8.3 x 25.4 cm)
90° elbow =
5 ft. (1.5 m)
90° elbow
2 ft. (0.6 m)
*
If 7" (17.8 cm) round vent is used, maximum length of vent
system is 80 ft. (24.4 m).
Recommended standard fittings
90° elbow =
45° elbow =
5 ft. (1.5 m)
2.5 ft. (0.8 m)
4
wall cap
Maximum length
1 - 90° elbow
8 ft. (2.4 m) straight
1 - wall cap
Length of 3-1/4" x
10" (8.3 x 25.4 cm)
system
3-1/4" x 10"
3-1/4" x 10"
(8.3 x 25.4 cm)
(8.3 x 25.4 cm)
flat elbow =
wall cap =
12 ft. (3.7 m)
0 ft. (0 m)
6" (15.2 cm) vent system
wall cap
6 ft. (1.8 m)
Maximum length*
1 - 90° elbows
1 - wall cap
8 ft. (2.4 m) straight =
Length of 6"
(15.2 cm) system
3-1/4" x 10"
6" (15.2 cm)
(8.3 x 25.4 cm) to
wall cap =
6" (15.2 cm) =
0 ft. (0 m)
4.5 ft. (1.4 m)
= 70 ft. (21.3 m)
= 5 ft. (1.5 m)
= 8 ft. (2.4 m)
= 0 ft.
(0 m)
= 13 ft. (3.9 m)
=
70 ft. (21.3 m)
=
5 ft. (1.5 m)
=
0 ft.
(0 m)
8 ft. (2.4 m)
=
13 ft. (3.9 m)
3-1/4" x 10"
(8.3 x 25.4 cm)
to 6" (15.2 cm)
90° elbow =
5 ft. (1.5 m)
Now start...
With range hood in kitchen.
Slide cardboard or hardboard under
range before moving range across
floor to prevent damaging floor
covering.
Cover countertop, cooktop or set-in
range with a thick, protective covering
to prevent damaging them.
1.
Disconnect and move
freestanding range from cabinet
opening to provide easier access
to upper cabinet and rear wall. Put
a thick, protective covering over
cooktop, set-in range or
countertop to protect from
damage or dirt.
2.
Determine which venting
method (roof or wall venting or
non-venting) you need to use. This
range hood is shipped for vented
installation.

Prepare hood

location
wood filler strips
(recessed cabinet
bottoms only)
3"
(7.6 cm)
cabinet
bottom
3"
wall
(7.6 cm)
3.
If cabinet has recessed
bottom, add wood filler strips on
each side. Locate screws to attach
filler strips in locations shown.