Install Hood Liner Internal Blower Motor
1. Install the hood liner blower motor assembly inside the hood
liner canopy with the wiring connection to the left for the
single motor system and to the front or top for the dual motor
system.
Single Blower Motor Assembly
3=
Run the power supply wires and connector from the range
hood through the hole in the right end of the motor mounting
plate.
A
j_
A
A. Wiring connection
Dual Blower
Motor
Assembly
A
J
A. Wiring connection
2. Slide the left mounting plate flange under the motor mounting
bracket.
4=
5=
A. Motor mounting plate hole
B. Power supply wires and connector
Push the right end of the motor mounting plate up and snap it
into the spring tab.
NOTE: The spring tab should be outside the slot in the
mounting plate.
J
A. Motor mounting plate
B. Spring clip
Align mounting holes in motor mounting plate with motor
mounting clip nuts and install 6 x 16 mm screws and
6.4 mm lock washers (quantity 2 for single motor; quantity 5
for dual motor).
A
B
A. Motor mounting bracket
B. Mounting plate left flange
ci
h
A. Screw with lock washer
B. Mounting hole in motor mounting plate
C. Clip nut (6 mm)