10. Attach Vent Damper or Transition
7" (17.8 cm) Round Vent Mounting Plate
B
Using (2) short Phillips head screws, install the 7" (17.8 cm)
■
round vent mounting plate over the vent knockouts removed
in Step 8. Position the wide flange (C) to the front.
NOTE: An optional 7" (17.8 cm) round damper (A), Part
Number W10355451, and a 7" (17.8 cm) round vent
mounting plate (B), Part Number W10388168, are available
as accessories. For information on ordering, see the
"Assistance or Service" section.
If installing the optional round damper, position it over the
■
round vent mounting plate.
11. Mount Range Hood
Lift the range hood into place, positioning the rear slots over
■
the mounting brackets.
Using a Phillips screwdriver, push on the screws that are
■
started into the top mounting tabs and bend the tabs against
the cabinet side walls. Attach the screws to the cabinet side
walls.
For direct wire installations, run the home power supply
■
cable according to the National Electric Code or CSA
standards and local codes and ordinances. There must be
enough wiring from the fused disconnect (or circuit breaker)
box to make the connection in the range hood electrical
terminal box.
A
C
Tighten the strain relief screws.
■
NOTE: Do not reconnect power until the installation is
complete.
OPTIONAL: If you prefer, bend the rear tabs against the rear
of the range hood and attach to the wall using #8-18 x 5/8"
(4.2 x 16 mm) truss-head screws.
12. Connect Vent System
Connect the ventwork to the range hood. Seal joints with
■
vent clamps or duct tape to make secure and airtight.
Check that the back draft dampers work properly.
■
13. Make electrical connection
Option 1 - Direct Wire Installations
Use a UL listed/CSA approved wire connector and connect
■
the 2 white wires (A) together.
Use a UL listed/CSA approved wire connector and connect
■
the 2 black wires (B) together.
WARNING
Fire Hazard
Electrically ground the blower.
Use copper wire.
Connect ground wire to green ground screw in
terminal box.
Failure to do so can result in death, fire, or
electrical shock.
Connect the green (or bare) ground wire (C) from the power
■
supply to the green ground screw in the electrical box and
tighten the screw securely.
Reinstall the electrical box cover.
Reconnect power.
A
B
C