Whirlpool WVW75UC6DS Installationsanleitung und Gebrauchs- und Pflegeanleitung - Seite 4

Blättern Sie online oder laden Sie pdf Installationsanleitung und Gebrauchs- und Pflegeanleitung für Lüftungshaube Whirlpool WVW75UC6DS herunter. Whirlpool WVW75UC6DS 28 Seiten. 36" (91.4 cm) island-mount canopy range hood
Auch für Whirlpool WVW75UC6DS: Gebrauchs- und Pflegeanleitung Installationsanleitung (28 seiten), Installationsanleitung und Gebrauchs- und Pflegeanleitung (32 seiten)

Whirlpool WVW75UC6DS Installationsanleitung und Gebrauchs- und Pflegeanleitung

Tools and Parts

Gather the required tools and parts before starting
installation. Read and follow the instructions provided
with any tools listed here.
Tools Needed
Level
Drill with 1
/
" (3.2 cm),
1
4
and
/
" (7.9 mm) drill bits
5
16
Pencil
Wire stripper or utility knife
Tape measure or ruler
Pliers
Caulking gun and weatherproof caulking compound
Vent clamps
Jigsaw or keyhole saw
Flat-blade screwdriver
Metal snips
Phillips screwdriver
Parts Needed
Home power supply cable
/
" (12.7 mm) UL listed or CSA approved strain relief
1
2
3 UL listed wire connectors
For Vented Installations, You Will Also Need:
1 wall or roof cap
Metal vent system
For Non-Vented (Recirculating) Installations,
You Will Also Need:
Recirculation Kit Part Number W10294733 for non-vented
(recirculating) installations only. See "Assistance or Service"
section to order.
6" (15.2 cm) diameter round metal vent duct -
length required is determined by ceiling height.
Parts Supplied
Remove parts from packages. Check that all parts are included.
Hood canopy assembly with blower, lights and canopy glass
already installed.
Vent transition with back draft dampers installed
Metal grease filter
Vent cover support bracket
Mounting template
2-piece vent cover
4 - 4.2 x 8 mm screws
6 - 5 x 45 mm mounting screws
2 - 3.5 x 9.5 mm mounting screws
2 - 8 x 40 mm wall anchors
4 - 10 x 60 mm wall anchors
4 - 5.4 x 75 mm screws (for 10 x 60 mm wall anchors)
T10 Torx
adapter
®†
T20
Torx
adapter
®†
®
4

INSTALLATION REQUIREMENTS

/
" (3.2 mm),
1
8

Location Requirements

IMPORTANT: Observe all governing codes and ordinances.
Have a qualified technician install the range hood. It is the
installer's responsibility to comply with installation clearances
specified on the model/serial/rating plate. The model/serial/
rating plate is located behind the left filter on the rear wall
of the vent hood.
Canopy hood location should be away from strong draft areas,
such as windows, doors and strong heating vents.
Cabinet opening dimensions that are shown must be used.
Given dimensions provide minimum clearance.
This range hood is recommended for use with cooktops with
a maximum total rating of 60,000 BTUs or less.
Grounded electrical outlet is required. See "Electrical
Requirements" section.
The canopy hood is factory set for venting through the roof or
wall. For non-vented (recirculating) installation see "For non-
vented (recirculating) installation only" in the "Connect Vent
System" section. Recirculation Kit Part Number W10294733
is available from your dealer or an authorized parts distributor.
All openings in ceiling and wall where canopy hood will be
installed must be sealed.
For Mobile Home Installations
The installation of this range hood must conform to the
Manufactured Home Construction Safety Standards, Title
24 CFR, Part 328 (formerly the Federal Standard for Mobile
Home Construction and Safety, Title 24, HUD, Part 280)
or when such standard is not applicable, the standard for
Manufactured Home Installation 1982 (Manufactured Home
Sites, Communities and Setups) ANSI A225.1/NFPA 501A,
or latest edition, or with local codes.
Product Dimensions
10⁷⁄₈"
(27.6 cm)
20"
(50.8 cm)
TORX and T20 are registered trademarks of Acument Intellectual
®
Properties, LLC.
13³⁄₁₆"
(33.5 cm)
30" (76.2 cm) or
36" (91.4 cm)