fireStorm SEQ36 Benutzerhandbuch - Seite 12
Blättern Sie online oder laden Sie pdf Benutzerhandbuch für Aufnahmegeräte fireStorm SEQ36 herunter. fireStorm SEQ36 14 Seiten.
TRIGGER OUTPUT
The Trigger Output terminals can be used to connect the sequencer to another sequencer.
Several units can be chained for more shots. When operating in EQUAL and STEP mode the
Trigger Input pulses will be passed through to the second sequencer and so on.
The Trigger Output LED will light whenever there is a Trigger Output pulse.
Example 1
3 x 18 shot sequencers all in STEP mode require 3 x 18 = 54 Trigger Input pulses to fire all
channels.
Example 2
2 x 18 shot sequencers all in EQUAL [1x18] mode would require 2 x 18 = 36 Trigger Input
pulses to fire all channels
Example 3
3 x 18 shot sequencers all in EQUAL [3x6] mode would require 3 x 3 = 9 Trigger Input
pulses to fire all channels.
11 of 13