Firewarm stoves FIREWARM 8 Installations- und Betriebsanleitung - Seite 8

Blättern Sie online oder laden Sie pdf Installations- und Betriebsanleitung für Holzofen Firewarm stoves FIREWARM 8 herunter. Firewarm stoves FIREWARM 8 14 Seiten. Freestanding multifuel stoves
Auch für Firewarm stoves FIREWARM 8: Installations- und Betriebsanweisungen (16 seiten), Installations- und Betriebsanleitung (17 seiten)

Both the chimney and flue pipe must be accessible for cleaning and if ANy parts of the
chimney cannot be reached through the stove (with bafÍIe removed), a soot door must be
fitted in a suitable position to enable this to tre done.
Material
Clearances
The stove can be recessed in a suitable sized fireplace but a permanent free air gap of at
least 150mm must be left around the sides and top and at least 50mm at the back of the
stove to obtain maximum heat output and for access to the rear of the stove.
All non-combustible walls closer than 400mm to the stove should be at least TSmm thick
In all instances the back wall of the fireplace recess and Jhe hearth should be made of
non-combustible material.
Allow an apron of at least 300mm at the front of the stove and l50mm on either side.
The hearth on which the stove is to be placed should not be less than l25mm thick and
should tre in accordance with the current building regulations.
care should be taken to level the stove using the adjusting screws in the feet.
The appliance shall be installed on a floor with adequate load-bearing capacity . If the
existing construction does not meet this prerequisite, suitable measures (e.g. load
disturbing plate) should be taken to achieve it.
There should be NO combustible material within a distance of 700mm from any surÍ'ace
of the stove and these surf'aces should not exceed a temperature of B0 Degrees C.
Commissioning and Handover
Upon completion of the installationo allow a suitable period of time for any fire cement
and mortar to dry out. A small fire may then be lit and checked to ensure the smoke and
fumes are taken from the stove up the chimney and emitted safely to atmosphere. Do not
run the stove at full output for at least 3 4 days.
On completion of the installation and commissioning, ensure that the operating
instructions and operating tools for the stove are left with the customer. Ensure to
advise
the customer on the correct use of the appliance with the fuels likely to tle used on the
stove and warn them to use only the recommended fuels for the stove.
Advise Íhe user on what to do should smoke or fumes be emitted from the stove. The user
should be warned to use a suitable Íireguard in the presence of children, aged and/or
infirm persons.